![HP NonStop SSH 544701-014 Reference Manual Download Page 103](http://html.mh-extra.com/html/hp/nonstop-ssh-544701-014/nonstop-ssh-544701-014_reference-manual_165151103.webp)
HP NonStop SSH Reference Manual
Configuring and Running SSH2
•
103
The default is 0.
SOCKETSNDBUF
Use this parameter to control the size of the TCP/IP send buffer. When setting this parameter to a non-zero value the
specified parameter is used on a socket level.
Parameter Syntax
SOCKETRCVBUF
bytes
Arguments
bytes
A number representing the size of the TCP/IP send buffer in bytes. A value of 0 means the send buffer size
configured in the TCP/IP process is used.
Considerations
•
Setting this parameter to a higher value can increase throughput when transferring files. Normally the value
configured in the TCP/IP process is sufficiently high.
Default
The default is 0.
SOCKTCPMINRXMT
Use this parameter to control the minimum time for TCP retransmission timeout. When setting this parameter to a non-
zero value the specified parameter is used on socket level.
Parameter Syntax
SOCKTCPMINRXMT
time
Arguments
time
A number representing the minimum time for TCP retransmission timeout. A value of 0 means the minimum
time for TCP retransmission timeout configured in the TCP/IP monitor process is used.
Considerations
•
Normally the value configured on TCP/IP monitor process level (TCP-MIN-REXMIT-TIMEOUT) should be
sufficient, i.e. the default value should be used for parameter SOCKTCPMINRXMT. See document "HP
NonStop TCP/IPv6 Configuration and Management Manual" for details.
•
The Cluster I/O Protocols (CIP) subsystem does not support the corresponding socket option TCP_MINRXMT,
i.e. the default value must be used for parameter SOCKTCPMINRXMT if CIP is involved. See document "HP
NonStop TCP/IPv6 Configuration and Management Manual" for details.
Default
The default is 0.
SOCKTCPMAXRXMT
Use this parameter to control the maximum time for TCP retransmission timeout. When setting this parameter to a non-
zero value the specified parameter is used on socket level.
Summary of Contents for NonStop SSH 544701-014
Page 12: ...xii Contents HP NonStop SSH Reference Manual ...
Page 24: ...24 Preface HP NonStop SSH Reference Manual ...
Page 30: ...30 Introduction HP NonStop SSH Reference Manual ...
Page 46: ...46 Installation Quick Start HP NonStop SSH Reference Manual ...
Page 132: ...132 The SSH User Database HP NonStop SSH Reference Manual ...
Page 214: ...214 SSH and SFTP Client Reference HP NonStop SSH Reference Manual ...
Page 278: ...278 STN Reference HP NonStop SSH Reference Manual ...
Page 298: ...298 Monitoring and Auditing HP NonStop SSH Reference Manual ...
Page 302: ...302 Performance Considerations HP NonStop SSH Reference Manual ...