B-5
Cabling and Technology Information
Twisted-Pair Cable/Connector Pin-Outs
C
ab
lin
g and
Te
ch
nol
og
y
In
fo
rm
a
tio
n
Other Wiring Rules:
■
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be
twisted through the entire length of the cable. The wiring sequence must
conform to EIA/TIA 568-B (not USOC). See “Twisted-Pair Cable Pin
Assignments” later in this appendix for a listing of the signals used on each
pin.
■
For 1000Base-T connections, all four pairs of wires in the cable must be
available for data transmission. See
“Note on 1000Base-T Cable Require-
ments” on page B-2
for more information on 1000Base-T cabling.
■
For 10 Mbps connections to the ports, you can use Category 3, 4, or 5
unshielded twisted-pair cable, as supported by the IEEE 802.3 Type
10Base-T standard.
■
For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or
STP cable only, as supported by the IEEE 802.3u Type 100Base-TX
standard.
■
For 1000 Mbps connections, 100-ohm Category 5e or better cabling is
recommended.
■
To provide Power over Ethernet to the access point, all 4 pairs must be
connected for any network cable attached to this port; the cable must
meet ISO/DIS 11801 Class D requirements and IEEE 802.3af requirements.
Summary of Contents for J8168A
Page 1: ...Power over Ethernet ProCurve 2610 Switches Installation and Getting Started Guide ...
Page 2: ......
Page 3: ...HP ProCurve 2610 Switches Installation and Getting Started Guide ...
Page 9: ...vii D Recycle Statements Waste Electrical and Electronic Equipment WEEE Statements D 1 Index ...
Page 10: ......
Page 24: ......
Page 60: ......
Page 80: ......