2-22
Installing the Switch
Installation Procedures
In
sta
llin
g
th
e
Sw
itc
h
The following states provide status of the RPS and EPS ports.
600 RPS/EPS Connectivity
The following illustration shows an example of connectivity between an RPS/
EPS device and a switch device as a redundant AC power supply.
Remove the cover of the RPS input port and connect the RPS cable to the 600
RPS/EPS then to the 2610 switch.
Figure 2-13. Connecting a 600 RPS/EPS to a 2610 RPS
Fault (located on
the front)
Device
Connected
Power
Status
Message
Off
Off
Off
Nothing Connected
On or Off
Off
On
Not a valid state - should never happen
Off
On
Off
Switch is connected, RPS is available but
not required
Off
On
On
RPS is powering the connected device
Flashing
Off
Flashing
RPS/EPS port is in fault condition
Off
On
Flashing
Switch is requesting power, RPS can not
provide it. (N/A for EPS)
RPS input port
Switch RPS output port