Display Mode Configuration:
H - Hex mode
Current -> K - Keyword mode
T - Text mode
Enter new value, or [Q] to Quit:
6.
To decode the blinking state of system LED, review the entire SEL and look at events with
alert level 3 and above.
For example:
Log Entry 14: 01 Jan 1998 00:09:19
Alert Level 3: Warning
Keyword: EFI_SYSID_BMC_READ_ERROR
Cannot read a system ID
Logged by: System Firmware 0
Data: Status return from PDC function call
0x778002EF00E00150 0000000000000013
Log Entry 11: 01 Jan 1998 00:00:48
Alert Level 3: Warning
Keyword: EFI_SYSID_BMC_READ_ERROR
Cannot read a system ID
Logged by: System Firmware 0
Data: Status return from PDC function call
0x778002EF00E00100 0000000000000013
Log Entry 7: 23 Jun 2006 13:40:06
Alert Level 3: Warning
Keyword: PDH_INVALID_RTC_CLEARED
The RTC was found to be invalid and has been cleared
Logged by: System Firmware 0
Data: Data field unused
0x60800F8D00E00090 0000000000000000
Log Entry 4: 23 Jun 2006 13:39:35
Alert Level 3: Warning
Keyword: COOLING_UNIT_WARNING
Cooling unit warning
Logged by: Baseboard Management Controller;
Sensor: Cooling Device - Fan 11 (I/O)
Data1: transition to Non-Critical from OK
0x20449BEF17020050 FFFF01072B0A0300
NOTE:
Due to the type of server you purchased, your output may not exactly match the output
shown here.
Supported Configurations
This subsection provides a system build-up procedure.
System Block Diagram
The following is a system block diagram, showing the major rx2660 server functional components
and their interconnections:
There are two types of CRUs in the rx2660 server:
1) externally accessible CRUs (eCRUs)
2) internally accessible CRUs (iCRUs).
In the following two lists, asterisks identify those CRUs identifiable by System Insight Display
LEDs when they are faulty or have failed.