Table 5-3 Basic Low End Troubleshooting
(continued)
Action
Condition
Step
2 MP logs for events related to bulk power
supplies (see
“Power Subsystem ” (page 130)
for
details).
The preceding problem is fixed when the front
panel LEDs are as follows: system health is off,
internal health is off, external health is off, and
power is solid green.
A warning or critical failure has been detected
and logged after server powers on (system health
Both front panel system health and external health
LEDs are flashing amber.
2b
is flashing amber, internal health is off /solid
green, external health is flashing amber, and
power is steady green). Examine each power
supply LED. If not solid green, replace power
supply (see
“Power Subsystem ” (page 130)
for
details).
The preceding problem is fixed when iLO 2 MP
logs are read, and the front panel LED states are
as follows: system health is off, internal health is
off/ steady green, external health is steady green,
and power is steady green.
A fatal fault has been detected and logged after
server powers on (system health is flashing red,
Front panel system health LED is flashing red and
external health LED is flashing amber.
2c
internal health is off/steady green, external health
is flashing amber, and power is steady green). 1.
Examine each power supply LED. If not solid
green, replace power supply (see
“Power
Subsystem ” (page 130)
for details).
The preceding problem is fixed when iLO 2 MP
logs are read, and the front panel LED states are
as follows: system health is off, internal health is
off/steady green, external health is steady green,
power is steady green.
A warning or critical failure has been detected
and logged, while booting or running system
Both front panel system health LED and internal
health LED are flashing amber.
3a
firmware (system health is flashing amber,
internal health is flashing amber, external health
is steady green, and power is steady green). 1.
Check diagnostic LED panel to identify failed or
faulty internal CRU (See
“Troubleshooting Tools”
(page 113)
for more details).
The preceding problem is fixed when a
redundant, internal CRU is replaced, iLO 2 MP
logs are read, and the front panel LED states are
as follows: system health is off, internal health is
steady green, external health is steady green, and
power is steady green.
A fatal fault has been detected and logged, while
booting or running system firmware (system
Front panel system health LED is flashing red and
internal health LED is flashing amber.
3b
health is flashing red, internal health is flashing
amber, external health is steady green, and power
is steady green). 1. Check diagnostic LED panel
to identify failed or faulty internal CRU (See
“Troubleshooting Tools” (page 113)
for details.).
The preceding problem is fixed when a
redundant, internal CRU is replaced, iLO 2 MP
logs are read, and the front panel LED states are
as follows: system health is off, internal health is
110
Troubleshooting