Operations 18
b.
Disconnect each power cord from the server.
3.
Remove the bezel (on page
17
).
4.
Place the server on its side with the access panel facing up.
5.
Install the access panel:
a.
Place the access panel on the chassis, and slide it toward the front of the server.
b.
Tighten the thumbscrew.
6.
Close and lock the bezel ("
Install the bezel
" on page
16
).
Remove the access panel
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
1.
Power down the server (on page
16
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove the bezel (on page
17
).
4.
Place the server on its side with the access panel facing up.
5.
If installed, unlock and remove the Kensington security lock.
6.
Remove the access panel:
a.
Loosen the access panel thumbscrew.
b.
Slide the access panel back.