Table 20 Smart Array controller POST error codes
(continued)
Corrective action
Level
Description
Error
code
Follow the instructions in the error
message to correct the error condition.
Informational
Slot z Drive Array Recovery Needed.
The following disk drive(s) need Automatic Data
Recovery (Rebuild):
1786
Port 1I: Box 2: Bay 5
Select "F1" to continue with recovery of data to
drive(s).
Select "F2" to continue without recovery of data
to drive(s).
OR
Slot 1 Drive Array Recovery Needed
The following disk drive(s) need Automatic Data
Recovery (Rebuild):
Port 2I: Box 1: Bay 4
Automatic Data Recovery previously Aborted!
Select "F1" to retry Automatic Data Recovery.
Select "F2" to continue without starting Automatic
Data Recovery.
Replace the indicated disk.
Informational
Slot z Drive Array Operating in Interim Recovery
Mode. The following disk drive(s) should be
replaced:
1787
Port 1I: Box 3: Bay 1
Press
F1
to continue. The drive array
remains disabled.
Informational
Slot z Drive Array Reports Incorrect Drive
Replacement. The following disk drive(s) should
have been replaced:
1788
Press
F2
to reset configuration - all
data will be lost.
Port 1I: Box 2: Bay 1
Warning:
Pressing
F2
erases all data
in the array. Be sure you have a valid,
The following SCSI drive(s) were incorrectly
replaced:
current backup of the affected logical
drives before selecting this option.
Port 2I: Box 1: Bay 3
Press
F1
to continue. The drive array
remains disabled.
Informational
Slot z Drive Array Physical Drive(s) Not
Responding. Check cables or replace the following
physical drive(s):
1789
Press
F2
to fail drives that are not
responding. Interim Recovery Mode is
Port 1I: Box 1: Bay 8
enabled if configured for fault
tolerance.
None.
None
Slot z Drive Array - Valid Data Found in Array
Accelerator. Data will automatically be written to
drive array.
1792
The cache battery was depleted before
the system was returned to a state
Critical
Slot z Drive Array – Data in Array Accelerator has
been Lost
1793
where the cached data could be
Array Accelerator Battery Depleted
written to the array. Data loss may
occur.
(Error message 1794 will also be displayed.)
Replace the cache battery, if
necessary.
Informational if
battery bad;
otherwise None
Slot z Drive Array - Array Accelerator Battery
Charge Low.
Array Accelerator Posted-Write Cache is
temporarily disabled. Array Accelerator will be
reenabled when battery reaches full charge
1794
(or: Array Accelerator batteries have failed and
should be replaced)
114
Power-on Self Test (POST) error codes