Table 24 Smart Array P411 controller specifications
(continued)
NOTE: Support for greater than 2TB in a single logical drive.
64-bit, supporting servers memory space greater than 4 GB
Memory addressing
RAID 5 (Distributed Data Guarding)
RAID levels supported
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Upgradeable Firmware with Recovery ROM feature
Upgradeable firmware
256 MB (approximately 48 MB is used by the onboard processor)
Cache size
Table 25 Smart Array P700m controller specifications
Type I, 4-port, PCIe mezzanine board
Card type
11.3 cm x 10.0 cm x 2.0 cm (4.5 in x 4.0 in x 0.8 in)
Dimensions (excluding bracket)
Approximately 9.30 W
Maximum power required
15 minutes to 2 hours, depending on initial battery charge level
Time required to recharge battery
More than 2 days, with fully-charged batteries that are less than 3 years
old
Duration of battery backup
More than three years
Battery life expectancy
Spare battery part number
•
452348-B21 (for HP Integrity BL860c servers)
•
383280-B21 (for HP Integrity BL870c servers)
10º to 55º C (50º to 131º F)
Operating temperature range
-30º to 60º C (-22º to 140º F)
Storage/Shipping temperature range
10% to 90% (Storage/Shipping 5% to 90%)
Operating relative humidity (noncondensing)
0, 1, 1+0, 5, 6 (ADG)
RAID levels supported
108 external
Maximum number of physical drives (using
all four ports)
32
Maximum number of logical drives
Up to 2 GB/s in each direction
PCI Express transfer rate
Two external; each port has four 1x links
Number of SAS ports
Up to 1.2 GB/s per port in each direction
SAS transfer rate
3.0 Gb/s SAS
Drive types supported
512 MB (approximately 64 MB is used by the onboard processor)
Cache size
Table 26 Smart Array P711m controller specifications
Type I, 4-port, PCIe mezzanine board
Card type
10.1 cm x 11.4 cm x 2 cm (4 in x 4.5 in x 0.8 in)
Dimensions (excluding bracket)
Approximately 14 W
Maximum power required
10º to 55º C (50º to 131º F)
Operating temperature range
-30º to 60º C (-22º to 140º F)
Storage/Shipping temperature range
10% to 90% (Storage/Shipping 5% to 90%)
Operating relative humidity (noncondensing)
0, 1, 5, 6 (ADG), 5+0, 6+0
RAID levels supported
119