Table 20 Smart Array controller POST error codes
(continued)
Corrective action
Level
Description
Error
code
Check the array configuration.
Critical
Slot z Drive Array - Array Accelerator
Configuration Error. Data does not correspond to
this drive array
1795
Array Accelerator is temporarily disabled.
Check the cache module, and replace
if necessary.
Critical
Slot z Drive Array - Array Accelerator is Not
Responding.
1796
Array Accelerator is temporarily disabled.
The cache module has failed. Contact
your HP service representative for
assistance.
Critical
Slot z Drive Array - Array Accelerator Read Error
Occurred.
Data in Array Accelerator has been lost.
1797
Array Accelerator is disabled.
The cache module has failed. Contact
your HP service representative for
assistance.
Critical
Slot z Drive Array - Array Accelerator Self-Test
Error Occurred.
Array Accelerator is disabled.
1798
Press
F1
to continue with logical drives
disabled. See
.
Critical
Slot z Drive Array - Drive(s) Disabled due to Array
Accelerator Data Loss.
1799
Press
F2
to accept data loss and
re-enable logical drives.
Warning:
Pressing
F2
erases all data
in the array. Be sure you have a valid,
current backup of the affected logical
drives before selecting this option.
The cache module has failed. Contact
your HP service representative for
assistance.
Critical
179A-Slot z Drive Array – Array Accelerator is
disabled Unknown Problem Code).
Array accelerator is temporarily (permanently )
disabled.
1799
POST error codes