Specifications 89
BTUs per hour
2285 at 100V to 120V AC
input
2217 at 200V to 240V AC
input
Power supply output
Rated steady-state power
For more information, see
“Power supply specifications (on
page
89
).”
Rated peak power
For more information, see
“Power supply specifications (on
page
89
).”
*The system input requirements are based on measurements using hardware available at the publication
of this document. For updated information, see the HP website (
http://www.hp.com/go/proliant-energy-
efficient
).
Power supply specifications
The following specifications provide information on the parameters of the power supplies as they were
designed. For more information on configuring power for a specific server, see the HP website
(
http://www.hp.com/go/proliant-energy-efficient
).
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100V to 120V AC
200V to 240V AC
Rated input frequency
50Hz to 60Hz
Rated input current
5.5A at 100V AC
2.6A at 200V AC
Rated input power
526 W at 100V AC input
505 W at 200V AC input
BTUs per hour
1794 at 100V AC input
1725 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
Rated peak power
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
Summary of Contents for HP ProLiant DL385 G6
Page 1: ...HP ProLiant DL385 G6 Server User Guide Part Number 575045 001 April 2009 First Edition ...
Page 6: ...Contents 6 Customer Self Repair 92 Acronyms and abbreviations 100 Index 103 ...
Page 19: ...Component identification 19 For more information see Hot plug fan operation on page 26 ...
Page 52: ...Cabling 52 Cabling SAS hard drive cabling Battery cabling for BBWC ...
Page 73: ...Troubleshooting 73 ...
Page 98: ...Technical support 98 ...
Page 99: ...Technical support 99 ...