208
Field Description
Shutdown
High-temperature shutdown threshold. When the sensor temperature reaches the limit,
the system shuts down automatically.
display exception filepath
Use
display exception filepath
to display the directory for saving core files on an MPU.
Syntax
In standalone mode:
display exception filepath
[
slot
slot-number
[
cpu
cpu-number
] ]
In IRF mode:
display exception filepath
[
chassis
chassis-number
slot
slot-number
[
cpu
cpu-number
] ]
Views
Any view
Predefined user roles
network-admin
Parameters
slot
slot-number
: Specifies an MPU by its slot number. If you do not specify this option, the command
displays the directory for saving core files on the active MPU. (In standalone mode.)
chassis
chassis-number
slot
slot-number
: Specifies an MPU on an IRF member device. The
chassis-number
argument represents the member ID of the IRF member device. The
slot-number
argument represents the
slot number of the MPU. If you do not specify this option, the command displays the directory for saving
core files on the global active MPU. (In IRF mode.)
cpu
cpu-number
: Specifies a CPU by its number.
Examples
# In standalone mode, display the directory for saving core files on the active MPU.
<Sysname> display exception filepath
The exception filepath on slot 0 is flash:.
# In standalone mode, display the directory for saving core files on the standby MPU.
<Sysname> display exception filepath slot 1
The exception filepath on slot 1 is flash:.
# In IRF mode, display the directory for saving core files on the global active MPU.
<Sysname> display exception filepath
The exception filepath on chassis 1 slot 1 is flash:.
display fan
Use
display fan
to display the operating states of fans.
Syntax
In standalone mode: