189
display alarm
Use
display alarm
to display alarm information.
Syntax
In standalone mode:
display alarm
[
slot
slot-number
]
In IRF mode:
display alarm
[
chassis
chassis-number
slot
slot-number
]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot
slot-number
: Specifies a card by its slot number. If you do not specify this option, the command
displays the alarm information of all cards. (In standalone mode.)
chassis
chassis-number
slot
slot-number
: Specifies a card on an IRF member device by its slot number
and the member ID. If you do not specify this option, the command displays the alarm information for all
cards in the IRF fabric. (In IRF mode.)
Examples
# (In standalone mode.) Display alarm information.
<Sysname> display alarm
Slot Level Info
- ERROR Fan 1 is faulty.
- INFO Power 1 is absent.
Table 28
Command output
Field Description
Slot
Slot number of the card with an alarm. If the value is a hyphen (-), the alarm was
generated by the chassis. (In standalone mode.)
Level
Alarm severity. Possible values include
ERROR
,
WARNING
,
NOTICE
, and
INFO
, in
descending order.
Info
Detailed alarm information.
faulty
The card is starting up or is faulty.
# In IRF mode, display alarm information.
<Sysname> display alarm
Chassis Slot Level Info
1 - ERROR Chassis 1 fan 1 is faulty
1 - INFO Chassis 1 power 6 is absent.
1 1 ERROR Chassis 1 slot 11 temperature is too high, above the warning limit.
2 - ERROR Chassis 2 fan 1 is faulty