Setup and Installation Guide
www.hp.com
D-13
Troubleshooting
Table D-8: Is the Fan Health LED Green?
Answer
Possible Reasons
Possible Solutions
No, it is off.
The fan cable or connectors are
not properly connected.
Be sure that the connectors on the fan
cable are properly seated and not
damaged.
The Integrated Administrator
module is not properly seated.
Contact HP or your authorized
service provider for parts and
service.
No, it is red.
At least two fans have failed or
are not properly seated. You no
longer have adequate cooling.
Open the fan cage and look for
amber LEDs to determine which fans
have failed. Replace all failed fans.
Contact HP or your authorized
service provider for parts and
service.
No, it is amber.
At least one redundant fan has
failed. Your system still has
adequate cooling, but is no
longer redundant.
Contact HP or your authorized
service provider for parts and
service.
Yes, it is green.
All fans are functional.
Check your local or remote console
for error messages. Go to table D-6.
If these steps have not identified the
problem, contact HP or your
authorized service provider for
assistance.