3.13 config cables
Adds a new cable or verifies the configuration of all cables. This command assists in locating the
proper connector pair to connect the cable. The LEDs at each connector are lit until the next
connection is issued. This command also tests all cable connections if no parameter is given.
Syntax
config cable
[{-c1 <source_cabinet> -d1 <source_drawer> <source_port>}
[-c2 <dest_cabinet> -d2 <dest_drawer> <dest_port>]]
[-led {on, off}]
Arguments
-c1 <source_cabinet>
Cabinet number of the source 8P in hex.
-d1 <source_drawer>
Drawer number of the source 8P in hex.
-c2<dest_cabinet>
Cabinet number of the destination 8P in hex.
-d2 <dest_drawer>
Drawer number of the destination 8P or PCI drawer in
hex.
source_port
Either the IP port or IOP. IP port is denoted by N02,
N46, S13, S57, E67, W01. IOP is denoted by IOP<n>
dest_port
Either the IP port or PCI IOR. IP port is denoted by N02,
N46, S13, S57, E67, W01. PCI IOR is denoted by
IOR<n>
Options
-led {on, off}
The options on or off turn the LEDs on or off. By default, the LEDs
are on.
Examples
1. Verify all cable connections and turn off the LEDs.
MBM> config cables}
Configuring all cables...
Completed. Please use 'show cable' to view the configuration.
MBM>
2. Configure the cable between the south IP port of 8P drawer 1 on cabinet 0 and the north
IP port of 8P drawer 0 in cabinet 1. The LEDs for both ports are lit.
MBM> config cables -c1 0 -d1 1 S13 -c2 0 -d2 0 N02 #Turn on LEDs
MBM> config cables -c1 0 -d1 1 S13 -c2 0 -d2 0 N02 -led off #Turn off LEDs
MBM>