Load File Name
:main.bin
:main.bin
Target File Name
:main.bin
:main.bin
Server IP Address
:192.168.80.200
Local IP Address
:192.168.80.10
Gateway IP Address
:
FTP User Name
:
FTP User Password
:
Table 5-7
Description on the display information of setting Ethernet interface parameters
Display information
Description
'.' = Clear field
Shortcut key
.
is used to clear the current input.
'-' = Go to previous field
Shortcut key
-
is used to return to the previous field.
Ctrl+D = Quit
Shortcut key
Ctrl+D
is used to quit the parameter setting page.
Protocol (FTP or TFTP)
Choose to update application programs using FTP/TFTP
Load File Name
Name of the download file, which needs to be the same as that of the actual file
to be downloaded.
At the same time, you need to set the download path in FTP/TFTP.
Note that:
The first “main.bin” is the file name automatically remembered by the system at
the last update;
The second “main.bin” is the source file name set by the user.
An application file name including the extension such as .bin, cannot exceed 50
characters.
Target File Name
Name of the target file after the file is downloaded to the router. The extension
of the target file needs to be same as that of the downloaded file.
Note that:
The first “main.bin” is the file name automatically remembered by the system at
the last update;
The second “main.bin” is the source file name set by the user.
An application file name including the extension such as .bin, cannot exceed 50
characters.
Server IP Address
IP address of the FTP/TFTP server.
Local IP Address
IP address of the interface connected with the FTP/TFTP server.
Gateway IP Address
IP address of the gateway. You need not configure this IP address.
FTP User Name
FTP username, which will be used in FTP download. TFTP download needs no
username.
FTP User Password
FTP user password, which will be used in FTP download. TFTP needs no
password.
To use the default parameter after the colon, press
Enter
directly.
If the Ethernet port parameter settings fail to pass CRC check, the system adopts the default
settings and displays “Check net params crc error, use the default value.”
3)
After the above configuration, the system will automatically return to the Ethernet Parameter
Set sub-menu, where you can select
2