54
Updating the Hub Firmware
3. From the Main menu, enter
2
(Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
4. Enter
6
to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master DISABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
5. Enter
2
to change the Proxy Master setting to
ENABLED
and reboot the hub. When the
Main menu appears, verify the new Hub Controller version.
Procedure 6: Set Manufacturing Values
After resetting the hub and verifying the new firmware versions, set the
system.sysDescr
and
system.sysObjectID
values.
1. From the Main menu, enter
mfg
to display the Manufacturing Settings Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = ]
3. Set system OID [current = 1.3.6.1.4.1]
4. Toggle port bypass persistence mode [current = Enabled]
>
2. Enter
2
to display the Set sysDescr string Menu.
Set sysDescr string Menu: [current = ]
1. Return to Manufacturing Settings Menu
or enter new sysDescr string
>
Summary of Contents for A3724A - SureStore E Hub S10
Page 1: ...Hewlett Packard SureStore E Hub Models S10 and L10 Service and User Manual ...
Page 2: ......
Page 8: ...6 Regulatory Statements 110 Laser Safety 113 Glossary 117 Index 121 ...
Page 12: ...10 ...
Page 68: ...66 Viewing Hub Information ...
Page 86: ...84 If Firmware Upgrade Appears to Fail ...
Page 114: ...112 Regulatory Statements E VCCI Statement Japan ...
Page 118: ...116 Laser Safety Declaration of Conformity ...
Page 122: ...120 Glossary ...
Page 130: ...128 Index ...
Page 133: ......