175
LED codes
CUB detected ambient air errors
CUB detected ambient air errors
This section describes air errors detected by the monitoring utilities chip
(MUC) on the core utilities board after power-on.
Table 20
CUB detects ambient air error
LED
Fault
Symptoms
Corrective action
62
Ambient hot
1. Ambient air too hot.
2. Core utilities board (CUB) powers
down system.
3. Should have received “ambient
air too warm” error 69 prior to
this error.
• Check site temperature.
• Call the Response
Center.
63
OVERTEM
PMIB
1. MidPlane (MIB) too hot.
2. Core utilities board (CUB) sensed
overtemp on MidPlane power
board (MIBPB) and powers down
the system.
• Check that airflow is not
blocked.
• Check fans.
• Call the Response
Center.
64
QUADRL 0
1. Board overheated in Quadrant 0.
2. Core utilities board (CUB) sensed
overtemp in Quadrant 0 and
powers down the system.
Call the Response Center.
65
QUADRU 1
1. Board overheated in Quadrant 1.
2. Core utilities board (CUB) sensed
overtemp in Quadrant 1 and
powers down the system.
Call the Response Center.
66
QUADLL 2
1. Board overheated in Quadrant 2.
2. Core utilities board (CUB) sensed
overtemp in Quadrant 2 and
powers down the system.
Call the Response Center.
67
QUADLU 3
1. Board overheated in Quadrant 3.
2. Core utilities board (CUB) sensed
overtemp in Quadrant 3 and
powers down the system.
Call the Response Center.
Summary of Contents for 9000 V2500 SCA
Page 8: ...viii Table of Contents ...
Page 12: ...xii List of Tables ...
Page 42: ...20 Chapter1 Overview V2500 V2600 Cabinet Configurations ...
Page 56: ...34 Chapter2 Indicators switches and displays System Displays ...
Page 92: ...70 Chapter4 Firmware OBP and PDC HElp command ...
Page 158: ...136 Chapter6 HP UX Operating System Stopping HP UX ...