Appendix A
167
LED codes
Power on detected errors
03
FPGA not OK
1. Core Utilities Board (CUB)
monitoring utilities chip
(MUC) problem.
2. MUC cannot get correct
program transfer from
EEPROM on power up.
• Cycle the node power
using the Key switch.
• Call the Response
Center.
04
dc OK error
(Upper Left)
1. Power supply is reporting
failure (dc OK) after
keyswitch is turned on, but
prior to CUB power on
sequence.
2. This is the first of two or more
supplies reporting failure.
Call the Response Center.
05
dc OK error
(Upper Right)
1. Power supply is reporting
failure (dc OK) after
keyswitch is turned on, but
prior to CUB power on
sequence.
2. This is the first of two or more
supplies reporting failure.
Call the Response Center.
06
dc OK error
(Lower Left)
1. Power supply is reporting
failure (dc OK) after
keyswitch is turned on, but
prior to CUB power on
sequence.
2. This is the first of two or more
supplies reporting failure.
Call the Response Center.
07
dc OK error
(Lower Right)
1. Power supply is reporting
failure (dc OK) after
keyswitch is turned on, but
prior to CUB power on
sequence.
2. This is the first of two or more
supplies reporting failure.
Call the Response Center.
LED
Fault
Symptoms
Corrective action
Summary of Contents for 9000 V2500 SCA
Page 8: ...viii Table of Contents ...
Page 12: ...xii List of Tables ...
Page 42: ...20 Chapter1 Overview V2500 V2600 Cabinet Configurations ...
Page 56: ...34 Chapter2 Indicators switches and displays System Displays ...
Page 92: ...70 Chapter4 Firmware OBP and PDC HElp command ...
Page 158: ...136 Chapter6 HP UX Operating System Stopping HP UX ...