A-2
Specifications
Spec
ifi
cat
ions
Environmental
1
If you are installing J8177Ctransceiver, the operating ambient temperature must not exceed 40°C
(104°F) and must not exceed 35°C (99°F), if FIPS Opacity Shield is installed.
When a J9830A PSU is installed, the temperature rating is reduced to 40°C
above 5,000 ft.
Acoustic
5406R zl2 Switch and its bundles:
Geräuschemission LpA = 31.7 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LpA = 31.7 dB in a virtual workspace according to
DIN 45635 T.19
5412R zl2 Switch and its bundles:
Geräuschemission LpA = 35.7 dB am fiktiven Arbeitsplatz nach
DIN 45635 T.19
Noise Emission LpA = 35.7 dB in a virtual workspace according to
DIN 45635 T.19
Operating
Non-Operating
Temperature:
0
°
C to 45
°
C (32
°
F to 113
°
F)
1
-40
°
C to 70
°
C (-40
°
F to 158
°
F)
Relative humidity:
(non-condensing)
15% to 95% at 45
°
C (113
°
F)
15% to 95% at 65
°
C (149
°
F)
Maximum altitude:
up to 3.1 km (10,000 ft)
4.6 km (15,000 ft)