B-5
i.
The power supply auto-ranges to the AC voltage and frequency. It does not have to be reconfigured to operate over its rated
operating ranges.
Table B-10. Electrical Specifications.
Description
Specification
HP 9000 -
K100, K200, K400, K210,
K410, K220, & K420
HP 3000 -
939KS, 959KS, 929KS,
969KS/x00, & 969KS/x20
HP 9000 -
K250, K260, K450, & K460
HP 3000 -
979KS
AC Input Voltage Range
i
100 to 127 VAC or 200 to 240 VAC
90 to 143 VAC or 180 to 269 VAC
AC Input Line frequency
i
50 to 60 Hz
50 to 60 Hz
AC Input Current
12.5 A (max load at 100 VAC)
10.5 A (max load at 120 VAC)
6.0 A (max load at 200 VAC)
19.5 A (max load at 100 VAC)
16.0 A (max load at 120 VAC)
10.0 A (max load at 200 VAC)
AC Inrush Current
16 A peak, one cycle
48.65 A peak @ 140 VAC/60Hz
AC Input Power
1250 VA maximum
1700 VA maximum
Power Supply Output Rating
925 watts DC continuous
1200 watts DC continuous
Holdup without system reset
25ms at 50/60Hz (1 cycle, or 500ms)
20ms at 50/60Hz (1 cycle, or 500ms)
Battery Backup Time
15 minutes
With optional external PowerTrust UPS.
Without the optional UPS there is no
battery backup.
15 minutes
With optional external PowerTrust UPS.
Without the optional UPS there is no
battery backup.
Summary of Contents for 3000/9x9KS Series
Page 10: ...x ...
Page 38: ...A 4 Figure A 1 Space Planning Grid Sheet ...
Page 39: ...A 5 Figure A 2 System Cutouts ...
Page 70: ...B 28 ...
Page 75: ...C 5 Figure C 3 Space Planning Grid ...
Page 76: ...C 6 Figure C 4 K Class Equipment Profiles ...
Page 77: ...C 7 Figure C 5 T Class Equipment Profiles ...
Page 82: ...C 12 ...