PaRaMETER LIST FOR BIC 335 auTOMaTIC FunCTIOn DEVICE
Parameter
Description
Unit
Level
System setting values
47-TG classic (35)
47-TG classic (45)
47-TG classic (50)
47-TG classic (60)
47-TG classic (80)
47-TG
classic (
10
0)
47-TG
classic (
12
0)
Fan
33 P2EA Rising ramp of fan
min
–1
/s
OEM
10(00) 10(00) 10(00) 10(00) 10(00) 10(00) 10(00)
34 P2EB Downward ramp of fan
min
–1
/s
OEM
5(00) 5(00) 5(00) 5(00) 5(00) 5(00) 5(00)
35 P2EC
Maximum fan speed
min
–1
OEM
58(00) 58(00) 53(00) 55(00) 64(00) 65(00)
73(00)
36 P2ED Fan speed second phase of pre-aeration time
min
–1
OEM
29(00) 29(00) 27(00)
28(00) 32(00) 33(00) 35(00)
37
P2EE Fan speed after false start
min
–1
OEM
58(00) 58(00) 53(00) 55(00) 64(00) 65(00)
73(00)
38 P2EF Fan speed after shut-down in normal operation or blocking
min
–1
OEM
15(00) 13(00) 21(00) 13(00) 13(00) 14(00) 14(00)
39
P2EG
Fan speed first phase of pre-aeration time
min
–1
OEM
58(00) 58(00) 53(00) 55(00) 64(00) 65(00)
73(00)
40 P2EH
Minimum fan speed
min
–1
OEM
15(00) 13(00) 21(00) 13(00) 13(00) 14(00) 14(00)
41 P2EI Start rpm
min
–1
OEM
29(00) 29(00) 27(00)
28(00) 32(00) 33(00) 35(00)
42
P2EJ
Fan speed after locking
min
–1
OEM
58(00) 58(00) 53(00) 55(00) 64(00) 65(00)
73(00)
43 P2EK P factor, fan
min
–1
OEM
35(00) 35(00) 35(00) 35(00) 35(00) 35(00) 35(00)
44 P2EL I factor, fan
1s
OEM
12
12
12
12
12
12
12
45
P2EM Minimum PWM value
1%
OEM
5
5
5
5
5
5
5
Stepped modulation in heating operation
46 P2FA Time 1
1s
OEM
30
30
30
30
30
30
30
47
P2FB
Maximum load during time 1
1%
OEM
20
20
20
20
20
20
20
48 P2FC Time 2
1s
OEM
30
30
30
30
30
30
30
49
P2FD
Maximum load during time 2
1%
OEM
36
36
36
36
36
36
36
50 P2FE Time 3
1s
OEM
30
30
30
30
30
30
30
51 P2FF
Maximum load during time 3
1%
OEM
52
52
52
52
52
52
52
52 P2FG Time 4
1s
OEM
30
30
30
30
30
30
30
53 P2FH
Maximum load during time 4
1%
OEM
68
68
68
68
68
68
68
54 P2FI Time 5
1s
OEM
30
30
30
30
30
30
30
55
P2FJ Maximum load during time 5
1%
OEM
83
83
83
83
83
83
83
Other settings
56 P2GA
Configuration, action mode fault relays 0 = open 1 = closed
OEM
1
1
1
1
1
1
1
57
P2GB
Mains voltage selection 0 = phase/phase 1 = phase/neutral
OEM
1
1
1
1
1
1
1
58 P2GC Flue gas temperature blocking
1°C
OEM
100
100
100
100
100
100
100
59
P2GD
Maximum difference between flow and return
1°C
OEM
30
30
30
30
30
30
30
60 P2GE Waiting period after opening of the main gas valve or activa-
tion of the boiler room fan
1min HF
0
0
0
0
0
0
0
61 P2GF External main gas valve (poss. LPG valve)/
boiler room fan present 0=no 1=yes
HF
1
1
1
1
1
1
1
62 P2GG DHW charging (switch/pump)
0 = KKP+switch 1 = only DHW pump
HF
1
1
1
1
1
1
1
63 P2GH
Pump – minimum PWM value (increase if necessary)
1%
HF
35
35
35
35
35
35
35
64 P2GI
Pump – maximum PWM value (increase if necessary)
1%
HF
70
70
70
70
70
70
70
65
P2GJ
Three-way valve inverted 0=no 1=yes
HF
1
1
1
1
1
1
1
66
1)
P2EO
Air pressure switch fitted 0=no 1=yes
OEM
0
0
0
0
0
0
0
Adjustments for liquid gas
35 P2EC
Maximum fan speed
min
–1
OEM
53(00) 52(00) 50(00) 52(00) 58(00) 63(00)
70(00)
36 P2ED Fan speed second phase of pre-aeration time
min
–1
OEM
27(00)
26(00) 25(00) 26(00)
29(00)
32(00) 35(00)
39
P2EG
Fan speed first phase of pre-aeration time
min
–1
OEM
53(00) 52(00) 50(00) 52(00) 58(00) 63(00)
70(00)
40 P2EH
Minimum fan speed
min
–1
OEM
16(00) 15(00) 14(00) 14(00) 15(00) 16(00) 16(00)
41 P2EI Start rpm
min
–1
OEM
27(00)
26(00) 25(00) 26(00)
29(00)
32(00) 35(00)