5.2
Technical data
Hoval BioLyt
Type
(50)
(70)
(100)
(130)
(160)
• Daily heat output
3
kW
45
62
99
130
144
• Nominal output
kW
49
69
99
130
156
• Heat input at nominal output
kW
54
74
108
141
170
• Heat output area
kW
14-49
20-69
29-99
39-130
43-156
• Wood pellets acc. to EN ISO 17225-2 and EN plus A1 Ø
mm
6-8
6-8
6-8
6-8
6-8
Length
mm
5-30
5-30
5-30
5-30
5-30
Ash content
%
< 0.7
< 0.7
< 0.7
< 0.7
< 0.7
Fine content
%
< 1
< 1
< 1
< 1
< 1
• Maximum boiler operating temperature
°C
85
85
85
85
85
• Minimum boiler operating temperature
°C
60
60
60
60
60
•
Minimum boiler back flow temperature
°C
45
45
45
45
45
• Exhaust temperature
1
with nominal output
°C
170
170
160
170
185
• Exhaust temperature
1
with lowest nominal output
°C
90
90
80
90
100
• Carbon dioxide CO
2
%
12
12
12
12
12
• Operating/test pressure
bar
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
3.0/4.5
•
Boiler efficiency at nominal output
%
> 90
> 90
>90
>90
>90
•
Exhaust mass flow rate at nom. output water cont. pellets 10 %
kg/h
120
170
260
320
375
•
Exhaust mass flow rate at lowest nominal output
kg/h
38
53
82
98
112
• Flow resistance pellets boiler
z-value
1.5
1.5
0.4
0.3
0.3
• Upstream resistance at 10 K
mbar
25
55
30
39
52
• Upstream resistance at 20 K
mbar
7
16
8
10
13
•
Water flow at 10 K
m³/h
4.2
6.4
9.1
11.5
13
•
Water flow at 20 K
m³/h
2.1
3.2
4.5
5.7
6.7
• Boiler water content
litres
180
215
245
360
360
• Pellet hopper content
kg
130
130
105
130
130
• Ash area capacity
litres
65
65
120
180
180
• Thickness of insulation of boiler body
mm
80
80
80
80
80
• Boiler weight (
without
lagging, burner, pellets hopper)
kg
390
520
670
980
980
• Boiler weight (
with
lagging, burner, pellets hopper)
kg
640
780
950
1350
1350
Thermal flow safeguard
•
Switching point of thermal flow safeguard
°C
95
95
95
95
95
•
Minimal flow of water (cold water 10 °C)
m³/h
2.0
2.0
2.0
2.0
2.0
•
Minimum/maximum cold water flow pressure
bar
2/6
2/6
2/6
2/6
2/6
Exhaust plant
1
• Minimum downward boiler pressure
Pa
5
5
5
5
5
• Electrical intake capacity in operation
Watt
170
170
270
350
400
• Electrical intake capacity during ignition
Watt
1800
1800
1950
1950
1950
• Electrical intake capacity during introduction of pellets
Watt
1900
1900
1900
1900
1900
• Maximum current intake
2
A
13
13
13
13
13
• Sound power level
- heater noise (in installation room)
dB(A)
67
67
67
67
67
- burn-out noise (in installation room)
dB(A)
72
72
72
72
72
-
flue gas noise in the tube
dB(A)
82
82
82
82
82
-
flue gas noise radiated from the mouth
dB(A)
74
74
74
74
74
- pellet feed
dB(A)
73
73
73
73
73
1
The installation of a damper is generally recommended.
2
Min. 16 A protection because of operating current.
3
For configuration of the boiler in accordance with the off-periods of the suction turbine, filling times (BioLyt 50,70) and the burner cleaning times
of the boiler.
36
4 214 852 / 01
TEChnICAL InFORMATIOn
Summary of Contents for BioLyt 100
Page 7: ...7 4 214 852 01 NOTES...
Page 21: ...21 4 214 852 01 NOTES...
Page 51: ...51 4 214 852 01...