Menu navigation
Press the
Menu
key to display “Operator level” and “Service level”.
Use the
Select
key to confirm the “User level” selection and the
Arrow
keys to select and con-
firm the required sub-item.
Chimney sweep function
Press the
Manual operation/Chimney-sweep
key to turn on the illumination. The chimney sweep
function starts when you release the key. The boiler temperature is regulated to approx. 60ºC.
Press the individual menu key to run the boiler
at 30% (= part load) or at 100% output.
You can end this function by pressing the
Cancel
key or the
Manual operation/Chimney-sweep
key. It ends automatically after approx. 45 minutes.
Note: To ensure that heat dissipation is taking place, press the “Emission Measurement” key
on the TopTronic
®
T control!
User level
Service level
Time
Pellet feed opera-
ting mode
Pellet feed time
profile
Suction head chan-
geover
Menu
with enable time
with start time
no time control
Pellet feed off
automatic
mode
only suction
head 1
only suction
head 2
only suction
head 3
with enable time:
Start/End
with start time:
Start
(Only for trained service engineers)
Chimney sweep function
Output 30%
(Operating phases)
Cancel
Chimney sweep function
Output 100%
(Operating phases)
Cancel
51
4 204 827 / 02