3. Operation
"with start time"
After activating the setting “with start time” in the menu item “Feed
operating mode” (see sect. 3.8.1.2), you can adjust the start time
for the storage container refill in the menu item “Feed time profile”.
The storage container is filled every day at the predefined time. If
the storage container does not contain sufficient to last 24 hrs, it will
also be refilled in between.
Factory setting “Feed start time”: Start 20:00
Use the + or - keys to change the time in 1 minute intervals
(Fig. 77).
Press on the
yes
key to save the modified time (Fig. 78). The mes-
sage “Storing parameter value” appears for a few seconds (Fig. 79)
before moving back to the previous level. (Fig. 80).
You can leave this submenu or sub item by pressing the Back key
(Fig. 80) or waiting 45 seconds.
"no time control" or "Feed off"
After activating the setting “no time control” or “Feed off” in the menu
item “Feed operating mode” (see sect. 3.8.1.2), there are no adjust-
ments possible in the menu item “Feed time profile” (Fig. 81).
You can leave this submenu or sub item by pressing the Back key
(Fig. 81) or waiting 45 seconds.
5s
RESET
5s
RESET
5s
RESET
5s
RESET
5s
RESET
Fig. 79
Fig. 80
Fig. 78
Fig. 77
Fig. 81
Feed operating mode
with start time
Start
09:00
save
-
yes
no
+
Feed operating mode
with start time
Start
09:00
save
-
yes
no
+
3TORINGPARAMETER
VALUE
select
back
Time
Feed operating mode
Feed time profile
Suction head changeover
Feed operating mode
without time control
and/or feed off
back
31
4 204 827 / 02