English - 9
INSTALLATION
1. Place the bracket on the ceiling and mark drill holes through the slots in the base.
2. Drill two 5 mm (3/16-inch) holes at the marks and insert plastic plugs.
3. Run the mains wiring. Use wiring with conductors of 1 ~ 2.5 mm
2
cross-sectional area. Wiring should have an
insulation resistance of at least 300V.
4. Strip the conductor insulation to expose 5 mm of the conductor.
5. Slide open the terminal cover to access the terminal screws and install the wiring as shown in Fig. above.
1. (brown or black) L
220-240V phase
2. (yellow-green) E/LOOP
Earth or Loop
3. (Blue)
N
Neutral/interconnection -
4.
I
Interconn