6 - English
POSITIONING THE SMOKE ALARM
For the smoke alarm to give an early warning, it needs to be installed where the fire occurs. Housegard
therefore recommends that you install a smoke alarm in every room and on all floors.
»
Install a smoke alarm in all separate bedrooms and in rooms commonly occupied.
»
In homes with several storeys, a smoke alarm should be installed at the top of every staircase between
each storey.
»
In the basement, a smoke alarm should be installed on the ceiling at the foot of the stairs.
»
In bedrooms where people sleep with closed doors, there should always be a smoke alarm fitted in the
bedroom.
»
Install a smoke alarm in every room where there is a potential risk of fire.
»
Install a smoke alarm at each end of corridors, if they are longer than 9 metres.
»
Install the smoke alarm in the middle of the ceiling. If this is not possible, install the smoke alarm on
the wall at least 0.5 m from any corner and at least 10–15 cm from the ceiling. (Wall-mounting is not
recommended).
50 cm
100 cm
KEY:
Minimal protection
Recommended/more substantial protection
Smoke alarms with a pause function are recommended
Single-story residence, apartment
Multi story residence