20
3) Drain Timer
The Drain Timer is factory-adjusted, and no adjustment is required.
SETTING
TIME
Dip Switch
Dip Switch
No. 3
No. 4
T1
T2
OFF
OFF
10 seconds
150 seconds
ON
OFF
10 seconds
180 seconds
OFF
ON
10 seconds
120 seconds
ON
ON
20 seconds
180 seconds
T1: Time to drain the Water Tank
T2: Time to restrain defrost completion
4) Freeze Timer
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
Two new dip switches numbered 9 and 10 have been added to the improved “E” board to
better prevent possible freeze ups. These settings come factory set to the default setting
of 60 min. (OFF, OFF). Check the adjustment chart published in the Tech Specs for
proper settings. If the old board does not have these two dip switches, (only 8 instead of
10), leave setting as OFF, OFF.
SETTING
TIME
Dip Switch
Dip Switch
No. 9
No. 10
OFF
OFF
60 min.
ON
OFF
70 min.
OFF
ON
50 min.
ON
ON
60 min.