34
PROBLEM
POSSIBLE CAUSE
REMEDY
[5] No water
a) Water Supply Line
1. Water pressure too low and
1. Check and get
comes from
water level in Water Tank
recommended pressure.
Spray Tubes.
too low.
Water Pump
b) Water Solenoid
1. Dirty mesh filter or orifice
1. Clean.
will not start, or Valve
and water level in Water
freeze cycle
Tank too low.
time is too
c) Water System
1. Water leaks.
1. Check connections for
short..
water leaks, and replace.
2. Clogged.
2. Clean.
d) Pump Motor
1. Motor winding opened.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to Pump Motor
3. Check for loose
connection or open, and
replace.
4. Defective Capacitor.
4. Replace.
5. Defective or bound impeller. 5. Replace and clean.
e) Controller Board
1. Defective.
1. See “II.2. [ e ] CHECKING
CONTROLLER BOARD.”
[6] Fan Motor will
a) Fan Motor
1. Motor winding opened.
1. Replace.
not start, or is
2. Bearing worn out.
2. Replace.
not operating.
3. Wiring to Fan Motor.
3. Check for loose
connection or open, and
replace.
4. Fan blade bound.
4. Check and replace.
b) Controller Board
1. Defective.
1. See “II.2. [ e ] CHECKING
CONTROLLER BOARD.”
[7] All components a) Refrigerant
1. Undercharged.
1. Check for leaks and
run but no ice
recharge.
is produced.
2. Air or moisture trapped.
2. Replace Drier, and
recharge.
b) Compressor
1. Defective valve.
1. Replace.
c) Hot Gas Solenoid
1. Continues to open in freeze
1. Check and replace.
Valve
cycle.
d) Water Solenoid
1. Stuck open.
1. Replace.
Valve
2. Diaphragm bleed port
2. Clean or replace
clogged.
diaphragm.
e) Water Supply
1. Condenser water pressure
1. Check and get
Line [Water-cooled
too low or off and pressure
recommended pressure.
model only]
control opens and closes
frequently.
Summary of Contents for KM-150BAF
Page 5: ...5 I SPECIFICATIONS 1 KM 150BAF ...
Page 6: ...6 2 KM 150BWF ...
Page 7: ...7 II GENERAL INFORMATION 1 CONSTRUCTION a KM 150BAF ...
Page 8: ...8 b KM 150BWF ...
Page 14: ...14 Control Products HOSHIZAKI001 Board ...
Page 15: ...15 Control Products HOS 001A Board ...
Page 23: ...23 TEST PROGRAM OF ALPINE CONTROLLER BOARD ...
Page 25: ...25 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 150BAF ...
Page 26: ...26 b KM 150BWF ...
Page 30: ...30 4 PERFORMANCE DATA a KM 150BAF Air cooled ...
Page 31: ...31 b KM 150BWF Water cooled ...