48
13. REMOVAL AND REPLACEMENT OF PUMP MOTOR
Note: When replacing a Pump Motor with defective winding, it is recommended that a
new capacitor be installed.
1) Turn off the power supply, and unplug the icemaker.
2) Remove the Top Panel and Rear Panel.
3) Open the Bin Door.
4) Drain the Water Tank by removing the Rubber Tube and thumbscrew and pulling the
Tank forward and slightly down.
5) Release the Hose Clamp, and disconnect the Hose from the Spray Tube.
6) Remove the closed end connectors of the Pump Motor leads.
7) Remove the screw and the Pump Motor Bracket.
8) Lift up the Pump Motor with the Pump Motor Bracket.
9) Release the Hose Clamp, and disconnect the Hose for the Cleaning Water Valve.
10) Remove the four screws and the Pump Motor.
11) Install the new Pump Motor, and replace the removed parts in the reverse order of which
they were removed.
7) Remove the Fitting and the Gasket.
8) Release the Hose Clamp, and disconnect the Hose.
9) Remove the Water Valve from the Rear Panel.
10) Install the new Water Valve, and replace the removed parts in the reverse order of
which they were removed.
11) Replace the Top Panel in its correct position.
12) Open the Water Supply Line Shut-off Valve.
13) Plug in the icemaker, and turn on the power supply.
Summary of Contents for KM-150BAF
Page 5: ...5 I SPECIFICATIONS 1 KM 150BAF ...
Page 6: ...6 2 KM 150BWF ...
Page 7: ...7 II GENERAL INFORMATION 1 CONSTRUCTION a KM 150BAF ...
Page 8: ...8 b KM 150BWF ...
Page 14: ...14 Control Products HOSHIZAKI001 Board ...
Page 15: ...15 Control Products HOS 001A Board ...
Page 23: ...23 TEST PROGRAM OF ALPINE CONTROLLER BOARD ...
Page 25: ...25 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 150BAF ...
Page 26: ...26 b KM 150BWF ...
Page 30: ...30 4 PERFORMANCE DATA a KM 150BAF Air cooled ...
Page 31: ...31 b KM 150BWF Water cooled ...