10
2) Rinse thoroughly with clean water and wipe dry with a soft cloth.
3) Attach the grille back on the drip pan and fit them into the unit.
[d] SUCTION PUMP (WEEKLY)
IMPORTANT
1. The impeller must be replaced once a year. But the life cycle depends on
the running rate. Inspect the impeller well before the end of expected life
cycle. Operation with a defective impeller may result in dripping or improper
dispensing action.
2. The impeller must be sprayed with an alcohol disinfectant and assembled
into the casing immediately before restarting the unit. The impeller is made
of rubber. Do not leave it inside the casing for a long time without product or
with an alcohol disinfectant. The impeller may stick to the casing and fail to
turn or get damaged.
3. When the premix package becomes almost empty, the unit cannot operate
properly. Replace the premix package immediately. Operation with an empty
package will drastically reduce the impeller’s life cycle.
Cleaning
1) Open the front cover and remove the premix package. See “6. [c] PREMIX PACKAGE”
for details. The removed package must be stored in a refrigerator.
2) Place a container under the dispensing nozzle.
3) Press the dispense button to drain any premix remaining in the suction pump.
4) Repeat step 3) until no premix comes out.
5) Turn the nut securing the suction pump in the arrow direction and pull the suction pump
towards you.
6) If the shaft is dirty, wipe with a damp cloth, then a dry cloth.
Nut
Shaft
Casing