4
2. INSTALLATION
WARNING
To prevent possible water leak, electric shock or fire, the installation must be
carried out by qualified personnel.
[a] CHECKS AFTER INSTALLATION
* In the presence of the installer, check for proper installation according to the installation
manual provided.
* Receive the installation manual from the installer, and keep it for later reference.
[b] AMBIENT TEMPERATURE
Ambient temperature should be within 5 to 35°C. Operation of the unit for extended periods
outside of this normal temperature range may affect performance.
CAUTION
To avoid the risk of corrosion, clogging and health problems, be sure to use tap
water with a turbidity level of not more than 2.
[c] WATER PRESSURE
CAUTION
To prevent water leaks resulting in damage to the surrounding property, keep
the water supply pressure within 0.05 to 0.78 MPa.
[d] POWER SUPPLY
Power supply voltage:
220V AC
Voltage variation: 207 - 233V
Power supply capacity:
1.2 kVA
[e] CLEANING AND INSPECTION
* The product circuit has been cleaned before shipping. But clean it again before starting
up the unit, and check for proper installation of each part. See “5. MAINTENANCE AND
INSPECTION”.
* Check the wiring and piping before starting up the unit. See “5. MAINTENANCE AND
INSPECTION”.