18
T-1
Dispensed Amount of Hot Water
2.5 sec
Approx 100 mL
3.5 sec
Approx 150 mL
4.5 sec
Approx 200 mL
2) The dispensed amount of premix “T-2” is adjustable as follows. The dispensed amount
of premix will increase by about 11 g per second.
T-2
Dispensed Amount of Premix
1.2 sec
Approx 13 g
2.0 sec
Approx 22 g
2.8 sec
Approx 31 g
7. TROUBLE SHOOTING
IMPORTANT
If something seems wrong with the unit, check for possible causes according
to the following instructions. If the problem still exists, immediately contact an
authorized Hoshizaki service company.
When contacting a service company, let them know the model name, serial
number, date of installation (see warranty card) and state of the trouble.
[a] TROUBLES WITH ERROR CODE INDICATION
When the display shows an error code, check and correct the problem according to the
table below.
Code
Problem
Possible Cause & Remedy
E1
Heater
Thermistor
(1) The drain lever is left open.
Close the drain lever and reset the error code.
(2) The drain lever is closed.
Immediately contact an authorized Hoshizaki service company.
E2
Water Supply
(1) The drain lever is left open.
Close the drain lever and reset the error code.
(2) The water supply line shut-off valve is closed.
Open the valve and reset the error code.
(3) Low water.
Turn off the power switch. Check that the water supply is
restored. Turn on the power switch and reset the error code.
E3
Water Level
Switch
(1) The water level switch is defective.
Turn off the power switch and immediately contact an authorized
Hoshizaki service company.