SAFETY INSTRUCTIONS
1.1 The appliance you have purchased is a technologically advanced
product designed by one of the leading European manufacturers
of high pressure pumps. To obtain the best performance from your
unit, read this booklet carefully and follow the instructions each
time you use it We congratulate you on your choice and wish you
successful operation.
2
SAFETY RULES/RESIDUAL RISKS
2.1 SAFETY “MUST NOTS”
2.1.1
DO NOT use the appliance with
inflammable or toxic liquids, or any
products which are not compatible with the correct operation of the
appliance.
E
xplosion
or
poisoning
hazard
2.1.2
DO NOT direct the water jet towards people or
animals.
i
njury
h
azard
2.1.3
DO NOT direct the water jet towards the unit
itself, electrical parts or towards other electrical
equipment.
E
lEctric
s
hock
h
azard
2.1.4
DO NOT use the appliance outdoors in case of rain.
s
hort
c
ircuit
h
azard
2.1.5
DO NOT allow children or incompetent persons to use the
appliance.
i
njury
h
azard
2.1.6
DO NOT touch the plug and/or socket with wet
hands.
E
lEctric
s
hock
h
azard
2.1.7
DO NOT use the appliance if the electrical cable is
damaged.
E
lEctric
s
hock
a
nd
s
hort
c
ircuit
h
azard
2.1.8
DO NOT use the appliance If the high pressure hose
is damaged.
E
xplosion
h
azard
2.1.9
DO NOT jam the trigger in the operating position.
a
ccidEnt
h
azard
2.1.10
Check that the data plates are affixed to the appliance, if
not, Inform your dealer. Units without plates must NOT be
used as they are unidentifiable and potentially dangerous.
a
ccidEnt
h
azard
2.1.11
DO NOT tamper with or adjust the setting of the
safety valve or the safety devices.
E
xplosion
hazard
2.1.12
DO NOT alter the original diameter of the spray head
nozzle.
h
azardous
altEration
of
opErating
pErformancE
2.1.13
DO NOT leave the appliance unattended.
a
ccidEnt
hazard
2.1.14
DO NOT move the appliance by pulling on the
ELECTRICAL CABLE
.
s
hort
circuit
hazard
2.1.15 Make sure that cars do not drive over the high pressure hose.
2.1.16 DO NOT move the appliance by pulling on the high pressure hose.
E
xplosion
hazard
2.1.17 When directed towards tyres, tyre valves or other pressurised
components, the high pressure jet is potentially dangerous Do not
use the rotating nozzle kit, and always keep the jet at a distance of
at least 30 cm during cleaning.
E
xplosion
hazard
2.2 SAFETY “MUSTS”
2.2.1
All electrical conductors MUST BE PROTECTED against
the water jet.
s
hort
circuit
hazard
2.2.2
The appliance MUST ONLY BE CONNECTED to
an adequate power supply in compliance with all
applicable regulations.
E
lEctric
shock
hazard
Use of a safety residual current circuit-breaker (R.C.C.B.) will
provide additional protection for the operator (30 mA).
Models supplied without plug must be installed by qualified staff.
Use only authorized electrical extension leads with suitable
conductor gauge.
2.2.3
High pressure may cause parts to rebound: wear all the protective
clothing and equipment needed to ensure the operator’s safety.
i
njury
hazard
2.2.4
Before doing work on the appliance, REMOVE the plug.
a
ccidEntal
start
-
up
hazard
2.2.5
Before pressing the trigger, GRIP the gun firmly to
counteract the recoil.
i
njury
hazard
2.2.6
COMPLY WITH the requirements of the local water
supply company. According to EN 12729 (BA), the
appliance may only be connected to the mains
drinking water supply if a backflow preventer valve with drain facility
is installed in the supply hose.
c
ontamination
hazard
2.2.7
Maintenance and/or repair of electrical components MUST
be carried out by qualified staff.
a
ccidEnt
hazard
2.2.8
DISCHARGE residual pressure before disconnecting the
unit hose.
i
njury
hazard
2.2.9
Before using the appliance, CHECK every time that the
screws are fully tightened and that there are no broken or
worn parts.
a
ccidEnt
hazard
2.2.10
ONLY USE detergents which will not
corrode the coating materials of the
high pressure hose/electrical cable.
E
xplosion
and
ElEctric
shock
hazard
2.2.11
ENSURE that all people or animals keep a minimum
distance of 16 yd. (15m) away.
i
njury
hazard
Model
KPH-2.3EAS
Volt/Freq(V/Hz)
220/50
Working Pressure(Bar)
100
Max Pressure (Bar)
150
Motor Pow-er(W)
1900
Rate Flow(L/min)
5.5
Max Flow(L/min)
7.5
Motor Type
Universal
Pump RPM
3000
Summary of Contents for KPH-2.3EAS
Page 3: ...EN 2 OUT IN IN 1 min Optional Optional 1 2 inch 13mm Optional IN ON I CLICK FIG 2 ...
Page 4: ...EN 3 FIG 3 Optional Optional CLICK CLICK CLICK CLICK ...
Page 15: ...NL 14 UIT IN IN 1 min Optioneel Optioneel 1 2 inch 13 mm Optioneel IN AAN I KLIK FIG 2 ...
Page 16: ...NL 15 FIG 3 Optioneel Optioneel KLIK KLIK KLIK KLIK ...
Page 28: ...FR 27 FIG 3 En option En option CLIC CLIC CLIC CLIC ...
Page 40: ...DE 39 ABB 3 Optional Optional KLICK KLICK KLICK KLICK ...
Page 52: ...ES 51 FIGURA 3 Opcional Opcional CLIC CLIC CLIC CLIC ...
Page 64: ...IT 63 FIG 3 Opzionale Opzionale CLIC CLIC CLIC CLIC ...
Page 75: ...PL 74 WYJŚCIE WEJŚCIE WEJŚCIE 1 min Opcja Opcja 1 2 cala 13 mm Opcja WEJŚCIE WŁ I KLIK RYS 2 ...