UltraKey Lite Controller Installation and User Guide
Document 800-07422 Rev A
55
08/10
Note
If the controller cannot connect to the MAXPRO network, then this step
cannot be completed until the connection is established. However, the
MAXPRO settings menu can be configured even if the controller has not
connected to the MAXPRO network; that is, the LCD displays that MAXPRO is
offline.
5.
Use the LCD up/down arrow keys to select
RS232
or
RS422
, then press
Ent
.
6.
Use the LCD up/down arrow keys to scroll to an address between 1 and 99 to assign
to the controller, then press
Ent
to save.
7.
Press the down LCD arrow key to scroll to
Baud Rate
. Press
Ent
and use the
up/down arrow keys to select a baud rate of
9600
bps or
19200
bps for the controller.
Press
Ent
to save.
Note
19200 bps is the default baud rate for most MAXPRO systems.
8.
Press the down LCD arrow key to scroll to
Joystick Speed
. Press
Ent
and use the
up/down arrow keys to select
Normal
or
High
. Press
Ent
to save.
9.
Press the down LCD arrow key to scroll to
Serial Port
Mode
. Press
Ent
and use the up/down arrow keys to select
RS232
or
RS422
. Press
Ent
to save.
Note
In the following fields, you are setting the MAXPRO-Net Server IP address and
port number. To set the UltraKey Lite IP address or enter the main
configuration menus, press
Alt > Clr
.
10. Press the down LCD arrow key to scroll to
Server IP
. Press
Ent
and use the up/down arrow keys or the numeric keys to
enter the
Server IP
address. Press
Ent
to save.
11. Press the down LCD arrow key to scroll to
Server Port
.
Press
Ent
and use the up/down arrow keys or the numeric
keys to enter the
Server Port
Address. Press
Ent
to save.
12. After the MAXPRO settings are complete, press
Alt > Clr
to
exit the Setup menu.
Step 4: Configure MAXPRO Mode Default Settings While Powering Up
1.
While powering up, when the
Time Left 3
menu displays,
press
Alt > Monitor
to set the Maxpro mode.
2.
Set the corresponding serial port as:
Maxpro Settings
SerialPortMode:
Maxpro Settings
Server IP:
MaxproServer IP
_59.099.251.132
Maxpro Settings
Server Port:
Time Left 3
Summary of Contents for UltraKey Lite HJC5000
Page 2: ......
Page 3: ...Installation and User Guide ...
Page 10: ...10 ...
Page 14: ...14 ...
Page 30: ...30 Using the UltraKey Lite Controller ...
Page 46: ...46 Installing UltraKey Lite with VideoBloX ...
Page 71: ......