Figure 6-8 (Sheet 2).
Configuration Data
(d) CONFIGURATION DATA Page 3 (Figure 6-8, sheet 3):
1
General
a
For CONFIGURATION DATA pages 3 thru 10, the strap setting value 0
or 1 in parentheses is as follows: 1= open circuit; and 0 = tied to
common.
2
Data Fields
a
Line 4
(1) This line displays A(0) ICAO ADRS AVAIL or A(1) ICAO ADRS NOT
AVAIL left-justified as determined by the state of system
configuration pin TP10A.
b
Line 6
(1) This line displays B(0) FMC1 CONNECTED or B(1) FMC1 NOT
CONNECTED left-justified as determined by the state of system
configuration pin TP10B.
c
Line 8
(1) This line displays C(0) FMC2 CONNECTED or C(1) FMC2 NOT
CONNECTED left-justified as determined by the state of system
configuration pin TP10C.