background image

 

OPERATOR MANUAL // TABLE  OF CONTENTS 

 

HONEYWELL 

TABLE OF CONTENTS 

  PAGE 

SECTION 1    FAM ILIARIZATION ..................................................................... 4 

1.1  Introduction...................................................................................... 4 
1.2  Stand-Alone Operation ..................................................................... 4 
1.3  FS2000 System Operation ................................................................ 4 
1.4  Overview ......................................................................................... 5 

1.4.1 

Model SS4-AI Infrared Flame Detector ................................. 5 

1.4.2 

Detection Range .................................................................. 5 

1.4.3 

Field-of-View ....................................................................... 5 

1.4.4 

Configuration Settings ......................................................... 5 

1.4.5 

Testing ................................................................................ 7 

SECTION 2    INSTALLATION .......................................................................... 8 

2.1  Installation Procedure ...................................................................... 8 

2.1.1 

Installation Precautions........................................................ 8 

2.1.2 

Conduit Installation .............................................................. 8 

2.1.3 

W iring Recommendations .................................................... 9 

2.1.4 

Power Supply Considerations............................................... 9 

2.2  Enclosure Installation ..................................................................... 10 
2.4  Configuring and W iring Detectors ................................................... 11 

SECTION 3    M AINTENANCE AND TROUBLESHOOTING ...............................14 

3.1  Personnel ...................................................................................... 14 
3.2  Cleaning W indowed Enclosures and Detectors ................................ 14 
3.3  Model SS4-AI Detector Faults......................................................... 15 

3.3.1 

Detector Faults .................................................................. 15 

3.4  Model SS4-AI Detector Module Replacement .................................. 15 
3.5  Detector Repair.............................................................................. 16 

DETECTOR  P INOUT  DA TA  .......................................................... 17 
TABLE 1:  Stand-Alone Model SS4-AI Detector Connectors 

Pinouts.............................................................................. 17 

TABLE 2:  Configuration Dip Switch Settings................................... 12 

 

INDEX .......................................................................................13 

Summary of Contents for SS4-AI

Page 1: ...Installation Guide and Operating Manual Infrared IR Digital Electro Optical Fire Detector Model SS4 AI For Special Applications Only Consult Factory Stand Alone Mode ...

Page 2: ...ptical Path Integrity CM1 CM1 A DartLogic FireLogic Fire Signature Analysis FireBusI FireBusII FirePic FirePicII FirePicIII FirePix FirePicture FSC Fire Sentry Corporation Fire Sentry Corp FSX All FSX Nomenclature Variations such as FS2 FS2X FS3 FS3X FS4 FS4X FS5 FS5X FS6 FS6X FS7 FS7X FS8 FS8X FS9 FS9X FS10X FS10X FS11 FS11X FS12 FS12X FS14 FS14X FS15 FS15X FS16 FS16X FS17 FS17X FS18 FS18X FS19 F...

Page 3: ...this bookset REFERENCE INTERNAL Identifies an additional source of information within this bookset Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the process CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may als...

Page 4: ... 1 1 Installation Precautions 8 2 1 2 Conduit Installation 8 2 1 3 Wiring Recommendations 9 2 1 4 Power Supply Considerations 9 2 2 Enclosure Installation 10 2 4 Configuring and Wiring Detectors 11 SECTION 3 MAINTENANCE AND TROUBLESHOOTING 14 3 1 Personnel 14 3 2 Cleaning Windowed Enclosures and Detectors 14 3 3 Model SS4 AI Detector Faults 15 3 3 1 Detector Faults 15 3 4 Model SS4 AI Detector Mod...

Page 5: ...d Suppression System 1 2 Stand Alone Operation For Stand Alone operation the Model SS4 AI Detector may be connected to a FM UL Approved Fire Security Panel The Model SS4 AI Detector operates on 24 volts DC The Model SS4 AI Detector when operated in the Stand Alone mode uses its Fire Fault and Verify optional relays to interface to FM UL Approved Fire Security Panels For Stand Alone operation the M...

Page 6: ...immediately and the second LED will rapidly blink for several seconds indicating that the Detector s FirePic is being permanently stored in the Detector s solid state memory FirePic is the several seconds of Detector data that preceded an alarm event Once the FirePic data is stored the second LED will remain on 1 4 2 Detection Range The detection range of the detector is field adjustable between 1...

Page 7: ...elay may be set in a Latching or Non Latching mode If Latching mode is set the Fire or Verify Relay will remain energized until the Detector is reset Powered down and up When Non latching mode is set the Fire Relay will reset after 10 seconds Unless the Verify Relay is enabled with a Verify Time then the Fire Relay will remain energized until the Verify Relay is energized or until the end of the v...

Page 8: ...ally all internal electronic systems The Model SS4 AI Detectors and the system they are connected to should be periodically manually tested to insure proper function of the entire Fire Protection System To test the Model SS4 AI Detectors manually where open fires are might be a safety hazard for both optical path and window cleanliness use a Honeywell Analytics Model FT 2145 Test Lamp ...

Page 9: ...nual for your Fire Control Panel 2 1 1 Installation Precautions The following precautions should be observed during installation of Model SS4 AI Detectors 1 Double check to make sure that the external electrical power is turned OFF before connecting to the Model SS4 AI Detector 2 Do not handle the Model SS4 AI Detector s module with its printed circuit boards without being adequately grounded Prin...

Page 10: ...s are necessary solder all splices The use of good wiring practices will greatly improve the ease of installation improve reliability and allow easier servicing 2 1 4 Power Supply Considerations The Model SS4 AI Detector uses 24 volts DC at a maximum current of 75 milliamps Make sure that the Panel s power supply can handle the current load of the total number of Model SS4 AI Detectors connected t...

Page 11: ... bracket is mounted with the correct orientation The outside contours of the mounting ears on the Detector enclosure and the ends of the bracket will match The large diameter of the threaded insert must be facing the enclosure d Screw the enclosure bracket assembly on to the ball stud Turn the Detector until the stud bottoms against the enclosure Do not tighten While holding the enclosure tighten ...

Page 12: ...Windowed Enclosures and Detectors Observe static protection safeguards while handling Model SS4 AI Detector modules Properly wear a wrist strap connected to earth ground 1 REMOVE THE DETECTOR MODULE FROM ITS ENCLOSURE a With electrical power off loosen the Allen head screw at the base of the metal enclosure top windowed cover Double check that electrical power is off by seeing that the Detector s ...

Page 13: ...Insert the cables into the metal enclosure base through one of the conduit openings Figure 5 Model SS4 AI Detector Wiring Bottom View of SS4 AI Detector Module b Then connect the 24 volt DC Power Supply wires into the J1 or J2 connector and firmly tighten down the two slotted screws with a small screwdriver DO NOT CONNECT ANY WIRES TO Pin 2 or Pin 3 Do NOT over tighten or the screws may strip or b...

Page 14: ...d If the Fire Verify option is used connect the Verify Fire Alarm wires to the four pin WECO terminal J6 Install the wires into J6 Pins 1 and 2 for Normally Open relays and firmly tighten down the slotted screws with a small screwdriver Refer to Figure 4 Model SS4 AI Detector Wiring for more details on relay connections 5 REPLACE THE DETECTOR MODULE INTO THE ENCLOSURE a Gently install the module b...

Page 15: ...closures and Detectors The optical windows on the Model SS4 AI Detector should be cleaned periodically on a regular maintenance schedule For clean applications this may be every month However for extremely dirty applications such as a truck filling station where black carboneous smoke can cover a nearby Detector a cleaning schedule of every day may be necessary Clean the windows on the Model SS4 A...

Page 16: ...heck voltage at the power connector J1 or J2 Pins 1 and 4 If no or very low voltage is measured check wiring and power supply e Detector Fault The Detector will Fault if any one of its Detectors fails the automatic built in test One LED is on until the fault is corrected Begin by thoroughly cleaning the Lens both inside and outside also clean the exposed surface of the Detector elements and the pr...

Page 17: ...ires to the new module Make sure the module is correctly aligned Gently re install back over the three metal standoffs Next re install the three chrome plated screws Be careful not to touch the Detector elements If they are accidentally touched clean as instructed in Section 3 2 Cleaning Windowed Enclosures and Detectors 7 Screw down the metal enclosure top windowed cover until it is secure and ti...

Page 18: ...ETECTOR POWER OUT PIN 1 DC Return or Ground 2 NOT USED Do not connect this Pin 3 NOT USED Do not connect this Pin 4 Power 24 Volts DC J4 FIRE RELAY PIN 1 Fire Relay Common 2 Fire Relay Normally Closed 3 Fire Relay Common 4 Fire Relay Normally Open J5 FAULT RELAY Energized PIN 1 Fault Relay Normally Open 2 Fault Relay Common 3 Fault Relay Normally Closed 4 Fault Relay Common J6 FIRE VERIFY RELAY PI...

Page 19: ...CH 4 DESCRIPTION open Non Latching mode If Verify is enabled then the Verify Relay will de energize approximately 10 seconds after it energizes If Verify is disabled then the Fire Relay s will de energize approximately 10 seconds after it energizes closed Latching mode If Verify is enabled then when the Verify Relay energizes it will remain energized until the detector is reset If Verify is disabl...

Page 20: ...Self Checking 15 E ESD 8 F FireBus 4 FireBus Wiring 9 Flame Detector See Detector 5 G Grounding 8 I Infrared IR Band 5 Installation 8 Conduit 8 Detector 11 Enclosure 10 Precautions 8 Static Damage 8 J Junction Box 8 9 L Layout Planning 8 M Maintenance 14 P Personnel Qualified 14 Power 9 R Relay Fault 17 Fire 17 Removing Modules 11 S Spectral Bands 5 Stand Alone 4 Static Damage 8 Swivel Mount 10 T ...

Page 21: ...enience commercial loss lost profits or savings or other incidental special or consequential damages arising out of or in connection with the use or inability to use such product to the full extent such may be disclaimed by law THIS WARRANTY DOES NOT COVER 1 Defects or damage resulting from use of the Product s in other than its normal and customary manner 2 Defects or damage from misuse accident ...

Page 22: ...lon Science Valley 1 43 Digital Ro 34 Gil Guro Gu Seoul 152 729 Korea Email analytics ap honeywell com Internet These Honeywell websites may be of interest to Industry Solution customers Honeywell Organization URL Corporate www honeywell com Honeywell Analytics www honeywellanalytics com Telephone Contact us by telephone at these numbers Organization Phone Number Americas Honeywell Analytics Inc 1...

Page 23: ...1998M0915 Rev A 072014 2014 Honeywell International Inc ...

Reviews: