4. Platform Servicing
4.4. Servicing Honeywell Options
64
PE SC1430-Based Honeywell Server PE SC1430-Based Honeywell Server
12/2007
Honeywell
Release Independent
Step
Action
4
Align the memory module’s connector with the alignment key on the
memory module socket, and insert the memory module in the socket.
Note: The memory module socket has an alignment key that allows you to
install the memory module in the socket in only one way.
5
Press down on the memory module with your thumbs while pulling up on
the ejectors with your index fingers to lock the memory module into the
socket.
When the memory module is properly seated in the socket, the ejectors
on the memory module socket align with the ejectors on the other sockets
that have memory modules installed.
6
Rotate the hard-drive carrier back into the system.
7
Rotate the card retention mechanism back into its original position and
push the tab down until it clicks into place.
8
Reconnect the P3 power cable connector beside the power supply.
9
Replace the cover.
10
Replace the server in the cabinet.
If using the server as a tower unit, return it to its proper location.
11
Reconnect the power cord and cables to the back panel of the server.
12
Press the Power On/Off button on the platform to turn the power back on.
13
Restart the Operating System.