background image

NOTI•FIRE•NET

™, 

IntelliQuad

™, and 

ONYXWorks

™ are trademarks; and

Acclimate® Plus™, FirstCommand

®, 

FlashScan

®, 

NOTIFIER

®, 

ONYX

®,

VeriFire®

, and 

VIEW

® are registered trademarks of Honeywell International

Inc. 

Microsoft

® and 

Windows

® are registered trademarks of Microsoft

Corporation. 

IBM

® is a registered trademark of IBM Corporation.

 ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.

Page 6 of 6 — Canadian DN-60085:J • 12/20/2013

This document is not intended to be used for 

installation purposes.   We try to keep our 

product information up-to-date and accurate. 

We cannot cover all specific applications or 

anticipate all requirements.  All specifications are 

subject to change without notice.

For more information, contact Notifier.

(888) 289-1114

10 Whitmore Road

Woodbridge, Ontario  LZL 7Z4

www.notifier.com

intelligent DCL equipment), and the Device Compatibility Docu-
ment. 

System Specifications 

S

YSTEM

 C

APACITY

Intelligent Digital Communications Loop (DCL) ................. 1

Intelligent detectors  ....................................................... 159

Addressable monitor/control modules ............................ 159 

Programmable internal hardware and output circuits  ........ 4

Programmable software zones ......................................... 99

Special programming zones ............................................. 14

LCD annunciators per FACP ............................................ 32

ACS annunciators per FACP ........ 32 addresses x 64 points

S

PECIFICATIONS

Primary  input  power

:

 120 VAC, 50/60 Hz, 5.0 A.

Current draw (standby/alarm):

NFS-320C board: 0.250 A. Add 0.035 A for each NAC in
use. 

KDM-R2 (Backlight on): 0.100 A.

Total output 24 V power: 6.0 A in alarm.

NOTE: 

The power supply has a total of 6.0 A of available power.

This is shared by all internal circuits.

Standard notification circuits (4): 1.5 A each.

Resettable regulated 24V power: 1.25 A.

Two non-resettable regulated 24V power outputs. One at
1.25 A and the other at 0.50 A.

Non-resettable 5V power: 0.15 A.

Battery charger range: 18 AH – 200 AH. Use separate cab-
inet for batteries over 26 AH.

Float rate: 27.6 V.

C

ABINET

 S

PECIFICATIONS

NFS-320C cabinet dimensions: 

Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025
cm) height; 5.81 in. (14.76 cm) depth. 

Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm)
height; 0.75 in. (1.905 cm) depth. 

When using trim ring TR-320, mount backbox with at least 1
inch (2.54 cm) between wall surface and front of backbox, to
allow door to open fully past the trim ring. The TR-320 molding
width is 0.905 in. (2.299 cm). 

S

HIPPING

 W

EIGHT

NFS-320C: 37 lb (16.78 kg) 

without batteries.

T

EMPERATURE

 

AND

 H

UMIDITY

 R

ANGES

This system meets NFPA requirements for operation at 0 –
49°C  and at a relative humidity 93% ± 2% RH (noncondens-
ing) at 32°C ± 2°C.  However, the useful life of the system's
standby batteries and the electronic components may be
adversely affected by extreme temperature ranges and humid-
ity.  Therefore, it is recommended that this system and its
peripherals be installed in an environment with a normal room
temperature of 15 – 27°C. 

A

GENCY

 L

ISTINGS

 

AND

 A

PPROVALS

The listings and approvals below apply to the basic NFS-320C
control panel. In some cases, certain modules may not be
listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.

UL/ULC Listed: 

S635 (UOJC).

FM Approved.

CSFM:

 7165-0028:0243.

FDNY:

 COA#6085, #6121.

Marine Applications:

 Marine approved systems must be con-

figured using components itemized in this document. (See
Main System Components, in “Product Line Information.) Spe-
cific connections and requirements for those components are
described in the installation document, PN 54756. When these
requirements are followed, systems are approved by the fol-
lowing agencies:

US Coast Guard: 

161.002/50/0, 161.002/55/0 (Standard

46 CFR and 161.002).

Lloyd's Register:

 11/600013 (ENV 3 category).

American Bureau of Shipping. 

NOTE: 

For information on marine applications, see DN-60688. 

S

TANDARDS

The NFS-320C complies with the following ULC Standards
and NFPA 72, International Building Code (IBC), and Califor-
nia Building Code (CBC) Fire Alarm Systems requirements:

ULC-S527-99.

LOCAL

 (Automatic, Manual, Waterflow and Sprinkler

Supervisory).

AUXILIARY

 (Automatic, Manual and Waterflow) (requires

TM-4).

REMOTE STATION

 (Automatic, Manual, Waterflow and

Sprinkler Supervisory) (requires TM-4).

PROPRIETARY

 (Automatic, Manual, Waterflow and Sprin-

kler Supervisory). 

Not applicable for FM.

CENTRAL STATION

 (Automatic, Manual, Waterflow and

Sprinkler Supervisory) (requires DACT).

EMERGENCY VOICE/ALARM

.

IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000

 (Seis-

mic). 

CBC 2007

 (Seismic).

Summary of Contents for NOTIFIER NFS-320C

Page 1: ...pliance Circuits NAC Selectable System Sensor S or Gentex strobe synchronization Built in Alarm Trouble Security and Supervisory relays VeriFire Tools online or offline programming utility Upload Download save store check compare and simulate panel databases Upgrade panel firmware Autoprogramming and Walk Test reports Optional universal 318 point DACT 80 character remote annunciators up to 32 EIA ...

Page 2: ...Automatic drift compensation of smoke sensor and CO cell High nuisance alarm immunity FSA 8000A INTELLIGENT FAAST DETECTOR Connects directly to the SLC loop of compatible ONYX series panels Provides five event thresholds that can be individually pro grammed with descriptive labels for control by event pro gramming uses five detector addresses Uses patented particle separator and field replaceable ...

Page 3: ...ak analog readings over a long period of time and setting the pre alarm level just above these normal peaks Cooperating Multi Detector Sensing A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre alarm decisions Without statistical sacrifice in the ability to resist false alarms it allows a sensor to increas...

Page 4: ...or Active LED Trouble LED and switch per circuit Active Alarm LEDs can be programmed by powered up switch selection by point to be red green or yel low the Trouble LED is always yellow See DN 6862 AEM 24AT Same LED and switch capabilities as ACM 24AT expands the ACM 24AT to 48 72 or 96 points See DN 6862 ACM 48A ONYX Series ACS annunciator up to 96 points of annunciation with Alarm or Active LED p...

Page 5: ...3 SLC IM SLC integration module for VESDAnet detectors See DN 60755 NETWORKING OPTIONS NCM W NCM F Standard Network Communications Mod ules Wire and multi mode fiber versions available See DN 6861 HS NCM W MF SF WMF WSF MFSF High speed Network Communications Modules that can connect to two nodes Wire single mode fiber multi mode fiber and media conver sion models are available See DN 60454 RPT W R...

Page 6: ... cm depth When using trim ring TR 320 mount backbox with at least 1 inch 2 54 cm between wall surface and front of backbox to allow door to open fully past the trim ring The TR 320 molding width is 0 905 in 2 299 cm SHIPPING WEIGHT NFS 320C 37 lb 16 78 kg without batteries TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 49 C and at a relative humidity 93 2 RH...