AS580 features
•
Spirit level on top of the back plate to correctly align the
AS580
•
Low profile polycarbonate box with the strobe lens
integrated into the lens
•
Quick release cradle contains the PCB for easy servicing
•
Highly weather resistant
•
Easy wiring
•
Easy diagnostics using the LEDs
•
Two siren standard
•
4.7
kΩ end of line (EOL) resistor built in
•
Tamper switch to protect against removal of cover or
removal from surface
Mounting Instructions
Use the spirit level included on the back plate to correctly align
the AS580.
Make sure that the tamper switch is properly fitted.
AS580 LEDs
Table 1: LED modes
Jled link
LED mode
Not cut
LED flashes (1Hz)
Cut
LED on steady
If an alarm is caused by a power or tamper failure, the LEDs
will operate as follows: 1 LED on steady, 1 LED flashes.
The LEDs can be turned off by removing the four-wire
(male/female) connector.
Board layout
Figure 1: Board layout
Wiring the CSx75 control panel
Figure 2: Wiring the CSx75 control panel
Wiring the CS250, CS2512, CS234, and
CS245 control panels
Figure 3: Wiring the CS250, CS2512, CS234, and CS245 control
panels
Note:
When the interconnection cable length exceeds 10 m,
program the siren tamper circuit as an isolated tamper loop
(Jtl jumper cut/open) and wire tamper pins TR and TL
individually to the CS panel:
•
TR = CS250 pin 23
•
TL = Aux. ground (GND)