background image

 

© 2019 UTC Fire & Security Americas Corporation, Inc. 

1 / 4  

P/N 146145999-

2 (EN) • REV E • ISS 28FEB19 

 

AS580 Sounder with Level Installation Sheet 

AS580 features 

• 

Spirit level on top of the back plate to correctly align the 
AS580 

• 

Low profile polycarbonate box with the strobe lens 
integrated into the lens  

• 

Quick release cradle contains the PCB for easy servicing 

• 

Highly weather resistant 

• 

Easy wiring 

• 

Easy diagnostics using the LEDs 

• 

Two siren standard 

• 

4.7 

kΩ end of line (EOL) resistor built in 

• 

Tamper switch to protect against removal of cover or 
removal from surface 

Mounting Instructions 

Use the spirit level included on the back plate to correctly align 
the AS580. 

Make sure that the tamper switch is properly fitted.

 

AS580 LEDs 

Table 1: LED modes 

Jled link 

LED mode 

Not cut 

LED flashes (1Hz) 

Cut 

LED on steady 

If an alarm is caused by a power or tamper failure, the LEDs 
will operate as follows: 1 LED on steady, 1 LED flashes. 

The LEDs can be turned off by removing the four-wire 
(male/female) connector. 

Board layout 

Figure 1: Board layout 

 

Wiring the CSx75 control panel 

Figure 2: Wiring the CSx75 control panel 

 

Wiring the CS250, CS2512, CS234, and 
CS245 control panels 

Figure 3: Wiring the CS250, CS2512, CS234, and CS245 control 
panels 

 

Note: 

When the interconnection cable length exceeds 10 m, 

program the siren tamper circuit as an isolated tamper loop 
(Jtl jumper cut/open) and wire tamper pins TR and TL 
individually to the CS panel: 

• 

TR = CS250 pin 23 

• 

TL = Aux. ground (GND) 

 