Degraded mode: In the unlikely event that the FACP’s
microprocessor fails, FlashScan detectors revert to
degraded operation and can activate the NAC circuits and
alarm relay. Each of the four built-in panel circuits includes a
Disable/Enable switch for this feature.
•
Multi-detector algorithm involves nearby detectors in alarm
decision (U.S. Patent 5,627,515).
•
Automatic detector sensitivity testing (NFPA-72 compliant).
•
Maintenance alert (two levels).
•
Self-optimizing pre-alarm.
FSL-751A VIEW (V
ERY
I
NTELLIGENT
E
ARLY
W
ARNING
)
S
MOKE
D
ETECTION
T
ECHNOLOGY
•
Advanced ONYX intelligent sensing algorithms differentiate
between smoke and non-smoke signals (U.S. Patent
5,831,524).
•
Addressable operation pinpoints the fire location.
•
Early warning performance comparable to the best aspira-
tion systems at a fraction of the lifetime cost.
FAPT-851A A
CCLIMATE
P
LUS
L
OW
-P
ROFILE
I
NTELLIGENT
M
ULTI
-S
ENSOR
•
Detector automatically adjusts sensitivity levels without
operator intervention or programming. Sensitivity increases
with heat.
•
Microprocessor-based technology; combination photo and
thermal technology.
•
Low-temperature warning signal at 40°F ± 5°F (4.44°C ±
2.77°C).
FSC-851 I
NTELLI
Q
UAD
A
DVANCED
M
ULTI
-C
RITERIA
D
ETECTOR
•
Detects all four major elements of a fire (smoke, heat, CO,
and flame).
•
Automatic drift compensation of smoke sensor and CO cell.
•
High nuisance-alarm immunity.
FSA-8000A
I
NTELLIGENT
FAAST D
ETECTOR
•
Connects directly to the SLC loop of compatible ONYX
series panels
•
Provides five event thresholds that can be individually pro-
grammed with descriptive labels for control-by-event pro-
gramming; uses five detector addresses.
•
Uses patented particle separator and field-replaceable filter
to remove contaminants.
•
Advanced algorithms reject common nuisance conditions
FCO-851A I
NTELLI
Q
UA
D
™ PLUS
A
DVANCED
M
ULTI
-C
RITERIA
F
IRE
/CO D
ETECTOR
•
Detects all four major elements of a fire.
•
Separate signal for life-safety CO detection.
•
Optional addressable sounder base for Temp-3 (fire) or
Temp-4(CO) tone.
•
Automatic drift compensation of smoke sensor and CO cell.
•
High nuisance-alarm immunity.
R
ELEASING
F
EATURES
•
Ten independent hazards.
•
Sophisticated cross-zone (three options).
•
Delay timer and Discharge timers (adjustable).
•
Abort (four options).
•
Low-pressure CO
2
listed.
Sample
System
Options
7112blok-201311.wmf
SLC Intelligent Loop
DEVICES
FSC-851A IntelliQuad
FAPT-851A Acclimate PLUS
FSL-751A FlashScan VIEW
FSP-851A Photo
FSI-851A Ion
FST-851A Thermal
FSA-8000A
.
..etc.
NBG-12LX
XP6A/10A I/O Modules
FMM-1 A
IDC
FDU-80
LCD2-80
Up to 32 remote displays
EIA-485
EIA-485
EIA-232
2048 annunciator/control points
Optional 318-point UDACT
Dual phone
lines to
Central
Station
ACM/AEM-24AT
LED Annunciator
LDM-32
Custom Graphics
ACM-8R
Relay Control
FCM-1A
NAC
FRM-1
Relay Contact
PRN Series Printer
NFS-320C