
Galaxy Flex Installer Manual
Keypad menu timeout
29
Keypad menu timeout
If you do not use the keypad for 5 minutes the system reverts to displaying the banner text.
This does not apply if you are logged in as Engineer (type 7).
Note:
In the Walk Test option the timeout is 20 minutes if no zones are tested or no keys
are pressed. In
66=PRE-CHECK
the timeout is 20 minute after the last zone has
been activated.
Engineer Mode
To program the control panel, the system must be in engineering mode, allowing access to
menu options
50=ENGINEER 1
,
60=ENGINEER 2
and
70=ENGINEER 3
.
If you are setting up and programming a control panel prior to handover, use the following
procedure to access engineering mode.
To enter Engineer Mode:
1.
Enter the default manager code, and then press
ent
.
2.
Press
48 ent 1 ent 1 ent 1 ent
to enable Engineer Mode. You have 5 minutes to carry
out the next step.
3.
Enter the default engineer code, and then press
ent
.
After handover the codes should have been changed and you will need to get a manager or
other type 6 user to carry out steps 1 and 2. See
Engineer Access [48]
for more details.
On accessing engineering mode, any group that is set becomes inaccessible. Set groups
cannot be assigned to zones, outputs and any other functions permitting group allocation.
When the engineer code is entered three things happen:
All system tampers become isolated.
You gain access to the full menu.
The banner message is changed to indicate engineer mode.
To exit from Engineer Mode:
1.
Return to the engineer banner.
2.
Enter your engineer code.
3.
Press
esc
.
Note:
If
esc
is pressed during the following system checks, the exit is aborted and the
system remains in engineering mode.
Before the normal banner is displayed the system performs these checks:
That there are no open zones or tampers. If there are tampers, they are displayed to
allow investigation. Open zones are not displayed.