Galaxy Flex Installer Manual
Communications [56]
127
2=Groups
Assign Groups to events so that the events have to occur in assigned groups
before they are signalled. Press
A
, the keypad displays
2=Group Settings
and
then press
ent
. The status of the groups assigned to the trigger is displayed. If
the group has Y below it, then this event occurring in this group is signalled.
If N is displayed, then the event is not signalled for that group. To toggle the
status of a group, enter the group number. When all the groups have been
assigned press
ent
to save the programming.
Cross Group Confirmation
Confirmed outputs (and channels in DTMF format, option 56.1.01.1) activate for alarms
across groups as long as both groups concerned have been assigned to that output or
channel. In the point ID signalling formats (SIA, Microtech and Contact ID), confirmed
signals are transmitted across groups that share the same account number. For example, in
option 56.1.01.2 (SIA), it is possible to select a different account number for each group on
the system. Group 1 and group 2 can be programmed with the same account number. If there
is a single activation in group 1 then a single intruder activation in group 2, within the
confirmed time window, a confirmed alarm signal is transmitted for group 2.
SIA Group Settings [56.1.01.2.level.2]
Note:
This option is only displayed if groups have been enabled (refer to
Options [63]
).
Event triggers are signalled, with the account number, to the telephone number programmed
in the
Account Number [56.1.03]
and
Telephone Number 1 [56.1.02]
options. However,
each group can be assigned a separate account number and programmed to transmit event
details to a unique telephone number. Select the required group, and then press
ent
.
SIA Group Settings Telephone Number [56.1.01.2.level.2.1]
To assign a telephone number to the group press
ent
, and then enter the required number.
The telephone number can be a maximum of 22 digits (including dial pause
and dial tone
detect
#
characters). Press
ent
to save the programming.
SIA Group Settings Account Number [56.1.01.2.level.2.1]
To assign an account number to the group, press
ent
, and then enter the required number.
The account number can be a maximum of six digits. Press
ent
to save the programming.
Account Groups
It is possible to have a number of groups bound by the same Account Number (an Account
Group). This means that one CL signal is not sent until all the groups within the Account
Group are set. Individual groups within the Account Group will not send a CL signal. The
groups within the Account Group are identified by a starred (
) Account Number, for
example,
2112.
When the Account Group is fully set, the identifier of the CL message is 999 to identify it as
an Account Group that has set.
When unset, each group that is part of the Account Group can report individually that it is
open.
Note:
Account Groups only operate for SIA signalling.