Appendix G: Peripherals
Galaxy Flex Installer Manual
228
MAX
4
reader
The MAX
4
is a proximity reader access control device for a single door, which can also be
used for setting and unsetting your alarm control panel. The MAX
4
can be configured in one
of two ways:
Standalone
In standalone mode the MAX
4
operates as an entirely independent unit and is not monitored
by the control panel for alarms, tampers or power failure. The MAX
4
, in this mode, is used
for door control or alarm system set/unset control, by connecting the internal relay output to
a door lock or an external relay. It is programmed and operated using MAX
4
proximity cards
or tags. The proximity cards and tags each have unique ID numbers and must be identified
to the MAX
4
before being used to operate the system. MAX
4
memory can store up to 999 ID
numbers, including at least three reserved for Masters. Once programmed, the ID numbers
of the tags and cards are stored in the MAX
4
memory until voided (removed) or erased.
Removing power from the MAX
4
does not erase the programming memory.
Note:
The MAX
4
defaults to standalone mode. It can be configured to online mode directly
from the control panel.
Online
The MAX
4
can operate in fully integrated online mode with the control panel,
communicating via the AB line to share system resources and facilities. In this configuration
the MAX
4
can be used for both door control and alarm system set/unset control, with
complete user traceability stored within the control panel. For detailed instructions on how
to program the MAX
4
onto the system, refer to the
MAX [69.2]
menu option.
Installing the MAX
4
Your MAX
4
pack contains the following:
MAX
4
proximity reader *
Drilling template
Installation instructions
Surge suppressor
* The MAX
4
is supplied with 3 metres of 12 wire E111235 AWG cable which is fixed and
sealed through a keyhole opening on the rear surface of the unit.
Mounting the MAX
4
To mount the MAX
4
use the step by step diagrams provided with the drilling template.
Use the drilling template as an aid to locate the holes required to secure the unit and insert
the connection cable.
The MAX
4
is fitted with an infrared lid tamper.