Installation and Setup Guide
8-4
Compatible 5800 Series Transmitters Table (cont’d.)
5804BD
Bi-Directional
Wireless Key
BR Only
•
House ID must be set.
•
Requires 5800TM Transmitter Module or 5883
Transceiver.
•
Can indicate system status via its 2 LEDs and
built-in sounder.
•
Has four pushbuttons, each with a unique input
(loop) code.
•
Operates the system similarly to wired
keypads.
5806
5807
5808LST
Wireless
Photoelectric Smoke
Detectors
RF
One-piece smoke detectors with a built-in
transmitter.
5809
Heat Detector
RF
One-piece rate-of-rise heat detector with a built-
in transmitter.
5816
5816MN
Door/Window
Transmitters
RF
Has two unique input (loop) codes: one for a
wired closed circuit contact loop; the other for its
built-in reed switch (used with a magnet).
5816TEMP
Low-Temp. Sensor
RF
Transmits a fault condition when temperature
drops below 45°F.
5817 Multi-Point
Universal
Transmitter
RF
Has three unique input (loop) codes: one for a
“Primary” contact loop with programmable
options; the others for two “auxiliary” closed
circuit contact loops.
5818 Recessed
Transmitter
RF
•
Reed switch magnetic contact sensor; easily
hidden in the frame and edge of a door or
window.
•
Has a single unique input (loop) code.
5819 Shock
Processor
Transmitter
RF
•
Connects to externally mounted inertia-type
shock detector (not supplied).
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Terminals for a wired, N.C. sensor
loop.
Loop 2: For a closed circuit contact loop using
the built-in reed switch in conjunction
with a magnet.
Loop 3: Terminals for a wired, closed circuit
contact loop.
5819WHS
5819BRS
Shock Processor
Transmitter
RF
•
Has built-in shock sensor.
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Built-in shock sensor loop wired to TB1
(normally closed).
Loop 2: For a closed circuit contact loop using
the built-in reed switch in conjunction
with a magnet.
Loop 3: Externally wired, closed circuit loop
connected to TB2.