Mounting and Operating Instructions Doorguard for MB panels BUS-2
10.5
Operating states and LED indication
10.5.1
Activate / de-activate Doorguard
If the door is open (DG2 triggered) activation is not possible!
Operating
9
Sequence
9
Duration
Operating state
Red LED
"Activation"
Green LED
"Operating state"
Doorguard active
Off
Lights up (static)
or
> 200 ms
Doorguard inactive
Reactivating the key
switch or operation via an
ID carrier, reactivates the
device.
Off
as per
programmed
"Door open
time"
Doorguard inactive
Lights up (static)
when door is
opened
Doorguard active when
programmed
"automatically"
Off
Lights up (static)
or
Doorguard active when
programmed
"manually"
Off
Lights up (static)
10.5.2
Permanent release
If manually de-activated, the door can be opened any number of times and remain open for any length
of time (deactivated without time limitation). Activation is performed using an ID pass card or key.
Operating
9
Sequence
9
Duration
Operating state
Red LED
"Activation"
Green LED
"Operating state
"
Doorguard active
Off
Lights up (static)
or
> 200 ms
Doorguard inactive
or
> 3 seconds
Permanent release*
Permanent release*
permanent door release
permitted, irrespective of
parameterization
Door open
–>LED lights up
Door closed
–>LED off
or
Stopp permanent
release
Doorguard active
Off
Lights up (static)