4-12
dummyhead
dummyhead
TROUBLESHOOTING
3A442
Battery cell low
temperature
protection
(at charging)
Battery cell overcools
resulting in battery not
being activated by itself
1. Battery cell temperature
(connected with Dr. H)
Cell temperature is 0°C
(32°F) or less
2. Battery indicator (single
unit)
ALERT (Orange)
indicator of battery pack
flashes, pressing check
button
Battery cannot be charged
due to charger left at low
temperature for long time
etc. (Charger side is
abnormal or not)
3. Battery charger (battery
pack installed)
Charger does not start
charging
4. Charger indicator (battery
pack installed)
ERROR (Red) indicator
of charger stays on
during charging
Low ambient temperature
of 0°C (32°F) or less
5. Battery peripheral area
(installed on charger)
Peripheral temperature is
0°C (32°F) or less
Damaged battery
6. Battery pack
Replace battery pack
3A443
Battery cell low
temperature
protection
(at discharging)
Battery cell overcools
resulting in battery not
being activated by itself
1. Battery cell temperature
(connected with Dr. H)
Cell temperature is -20°C
(-4°F) or less
2. Battery indicator (single
part)
ALERT (Orange)
indicator of battery pack
flashes, pressing check
button
PDU malfunction
3. PDU (battery pack
installed on power unit)
Motor operation by
performing the starting
procedure
4. PDU (power unit indicator)
(battery pack installed on
power unit)
ALERT (Orange)
indicator of power unit
flashes during
discharging (POWER
button pressed to ON)
Low ambient temperature
of -20°C (-4°F) or less
5. Battery peripheral area
(installed on power unit)
Peripheral temperature is
-20°C (-4°F) or less
Damaged battery
6. Battery pack
Replace battery pack
DTC
Detecting Item
Failure Condition/
Possible Cause
Verification Item (Check in numerical order)
Applicable Part
Check for
(abnormal symptom)
Summary of Contents for GXE2.0H
Page 8: ...MEMO dummyhead dummyhead ...
Page 22: ...MEMO dummyhead dummyhead ...
Page 27: ...4 1 4 dummytext 4 TROUBLESHOOTING TROUBLESHOOTING INFORMATION 4 2 DTC TROUBLESHOOTING 4 6 ...
Page 42: ...MEMO dummyhead dummyhead ...
Page 54: ...6 6 dummyhead dummyhead CONTROL UNIT STAYS MOUNT RUBBERS 5 6 3 5 2 9 7 1 3 2 8 1 4 3 3 3 ...
Page 58: ...MEMO dummyhead dummyhead ...
Page 67: ...8 1 8 dummytext 8 WIRING DIAGRAMS WIRING DIAGRAMS 8 2 ...
Page 70: ...MEMO dummyhead dummyhead ...