4-4
dummyhead
dummyhead
TROUBLESHOOTING
POWER UNIT INDICATOR
The power unit has the indicators for ALERT (Orange) [1] and ERROR
(Red) [2] along with the POWER indicator (Green) [3].
* Stop using the power unit and wait for it to cool down.
** The POWER button is pressed with the START/STOP switch in the START position when starting the power unit.
*** The protection function cancels automatically when the failure or abnormality is resolved.
[1]
[2]
[3]
(With Control Box)
Classifica
-
tion
Protection Function
Unit
Operation
Indicator
Indication
Condition
Indicator Reset
ERROR
(Red)
ALERT
(Orange)
POWER
(Green)
Malfunction
Regenerative resistance
circuit failure
Stop
Flash
–
–
When
detects
protection
function
item, then
lights
immediately
Turn off power unit
with POWER
button
or
After lighting for
1 minute, power
unit turns off
START/STOP switch
failure
Stop
Flash
–
–
CAN communication
interruption
Stop
Flash
–
–
Rotor sensor failure
Stop
Flash
–
–
Output pulse abnormality
Stop
Flash
–
–
Pre-charge circuit failure
Stop
Flash
–
–
FET thermistor shorted/
opened
Stop
Flash
–
–
Motor thermistor shorted/
opened
Stop
Flash
–
–
Error
FET overtemperature
abnormality
Stop
–
Flash
–
Motor overtemperature
abnormality
Stop
–
Flash
–
Motor lock failure
Stop
Flash
–
Motor overspeed (Except
S1, Q1, Q2 type)
Stop
Flash
–
Motor reverse rotation
(Except S1, Q1, Q2
types)
Stop
Flash
–
Overcurrent abnormality
(overload)
Stop
–
Flash
–
Undervoltage abnormality
Stop
–
Flash
–
Overvoltage abnormality
Stop
–
Flash
–
Electrostatic malfunction
Stop
–
Flash
–
Warning
FET overtemperature
warning
Continuing
operation*
–
Flash
Stay on
Cancels protection
function***
or
Turn off power unit
with POWER
button
or
After lighting for
1 minute, power
unit turns off
Motor overtemperature
warning
Continuing
operation*
–
Flash
Stay on
Misoperation
Starting interlock**
Stop
–
Flash
–
Turn off power unit
with POWER
button
or
After lighting for
1 minute, power
unit turns off
Summary of Contents for GXE2.0H
Page 8: ...MEMO dummyhead dummyhead ...
Page 22: ...MEMO dummyhead dummyhead ...
Page 27: ...4 1 4 dummytext 4 TROUBLESHOOTING TROUBLESHOOTING INFORMATION 4 2 DTC TROUBLESHOOTING 4 6 ...
Page 42: ...MEMO dummyhead dummyhead ...
Page 54: ...6 6 dummyhead dummyhead CONTROL UNIT STAYS MOUNT RUBBERS 5 6 3 5 2 9 7 1 3 2 8 1 4 3 3 3 ...
Page 58: ...MEMO dummyhead dummyhead ...
Page 67: ...8 1 8 dummytext 8 WIRING DIAGRAMS WIRING DIAGRAMS 8 2 ...
Page 70: ...MEMO dummyhead dummyhead ...