4-14
dummyhead
dummyhead
TROUBLESHOOTING
3A120
Lock error
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
Lock or overload by driven
system
2. Driven mechanism
Mechanical lock or
excessive overload
Loosely connected
connector
3. PDU 3P (Gray) connector
Loose or poor connection
Loosely connected
connector terminal
4. PDU 3P (Gray) connector
terminal
Loose or poor contact
Damaged stator coil
5. Stator coil
Coil resistance value
measurement (page 7-8)
Damaged PDU
6. PDU
Replace PDU
3A121
Motor
overspeed
Excessive overload driving
on downward slope
1. Driving situation of
completed machine
• Load weight
• Slope of working
condition
Traction driving by external
force
2. Driving situation of
completed machine
Traction operation
Damaged stator coil
3. Stator coil
Coil resistance value
measurement (page 7-8)
3A122
Motor reverse
rotation
Excessive overload driving
on upward slope
1. PDU (connected with Dr.
H)
Rotating direction
2. Motor P.T.O. shaft
Rotating direction
3-phase wire
misconnection
3. PDU 3P (Gray) connector
Wire connection (poor
connection of terminal or
connector)
Rotor sensor wire
misconnection
4. Rotor sensor 8P (Black)
connector
Wire connection (poor
connection of terminal or
connector)
3A130
FET overcurrent
(OC2)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
High ambient temperature
around product
2. PDU mounting area
Peripheral temperature
Lock or overload by driven
system
3. Driven mechanism
Mechanical lock or
excessive overload
Improper installation of
PDU on frame
4. PDU
PDU mounting condition
Damaged PDU
5. PDU
Replace PDU
3A131
FET
excessively
overheating
(OT2)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
High ambient temperature
around product
2. PDU mounting area
Peripheral temperature
Lock or overload by driven
system
3. Driven mechanism
Mechanical lock or
excessive overload
Improper installation of
PDU on frame
4. PDU
PDU mounting condition
Damaged PDU
5. PDU
Replace PDU
3A132
Motor
excessively
overheating
(OT2)
Overload operation
1. PDU (connected with Dr.
H)
Current value is 35 A or
more in motor running
status (abnormal)
High ambient temperature
around product
2. Motor peripheral area
Peripheral temperature
Lock or overload by driven
system
3. Driven mechanism
Mechanical lock or
excessive overload
Improper installation of
PDU on frame
4. PDU
PDU mounting condition
Damaged PDU
5. PDU
Replace PDU
DTC
Detecting Item
Failure Condition/
Possible Cause
Verification Item (Check in numerical order)
Applicable Part
Check for
(abnormal symptom)
Summary of Contents for GXE2.0H
Page 8: ...MEMO dummyhead dummyhead ...
Page 22: ...MEMO dummyhead dummyhead ...
Page 27: ...4 1 4 dummytext 4 TROUBLESHOOTING TROUBLESHOOTING INFORMATION 4 2 DTC TROUBLESHOOTING 4 6 ...
Page 42: ...MEMO dummyhead dummyhead ...
Page 54: ...6 6 dummyhead dummyhead CONTROL UNIT STAYS MOUNT RUBBERS 5 6 3 5 2 9 7 1 3 2 8 1 4 3 3 3 ...
Page 58: ...MEMO dummyhead dummyhead ...
Page 67: ...8 1 8 dummytext 8 WIRING DIAGRAMS WIRING DIAGRAMS 8 2 ...
Page 70: ...MEMO dummyhead dummyhead ...