HomeDefender HD-G005 Installation And User Manual Download Page 1

Printed in Hong Kong

PA: HD-G5/EN-Aug.2012-V1.1

HD-G005

PROTECT

YOUR HOME

INSTALLATION AND USER

MANUAL

GSM - SMS - RFID - TOUCH

Wireless Security Alarm System

SECURITY KIT GSM

Summary of Contents for HD-G005

Page 1: ...Printed in Hong Kong PA HD G5 EN Aug 2012 V1 1 HD G005 PROTECT YOUR HOME INSTALLATION AND USER MANUAL GSM SMS RFID TOUCH Wireless Security Alarm System SECURITY KIT GSM...

Page 2: ...etric sensor to protect doors and windows By adding specific devices the equipment can also operate safety functions such as the Remote Help for the elderly and protect home against gas or water leaks...

Page 3: ...thium batteries guarantee up to 15 hours stand by SMS alert for power failure power recovery and low battery Tamper protection Alarm System Positioning plan In order to ensure an efficient and secure...

Page 4: ...rooms to be entered and exited without setting off the alarm REMOTE SUPPORT function can be armed in emergency situations by means of the SOS panic button on the remote controls The siren will sound...

Page 5: ...to read the RFID devices without necessarily touching the panel SIM card slot 2 Inputs for wired sensors Output for Electronic lock Output for wired siren 500 mA Power plug On Off Switch Control Pane...

Page 6: ...s indicate wrong password Type the password again Disarm with RFID tags Induce RFID tag to the RFID area to disarm the system Control Panel functions Record Play Voice Memo The system enables a 10 sec...

Page 7: ...e holder in order to be informed by SMS of whom has disarmed the system Only one telephone number can be defined to receive the notification SMS 10 Command page 21 Nancy came home Nancy Speed Dial A s...

Page 8: ...into the slot located on the back of the control panel Send an SMS to the number of the card with the text IThe guide menu to the operations is received in reply The menu is available at 3 levels to e...

Page 9: ...mbers stored in the system will be recognised The 0 command disarms the alarm system The protected levels can now be accessed All the sensors are disarmed except for the sensors programmed in H24 Mode...

Page 10: ...l calls back the number from where the command came from Answer the phone call to be able to just listen or communicate by means of the alarm system SMS Command 3 Remote Monitoring Send The 00 command...

Page 11: ...This is to be certain to communicate the emergency Send The 6 command displays and records the 5 reference telephone for the emergency SMS s SMS Command 6 Store Alarm SMS No Forward Edit N B the syst...

Page 12: ...ly reports or the office manager SMS Command 7 Store SMS No for RFID Tags Send The 8 command stores the telephone number to speed dial call from the control panel Speed Dial Page 8 SMSCommand 8 StoreS...

Page 13: ...lature Zone 10 alarm Zone 11 alarm etc SMS Command 91 99 Change Zone Name 91 Zone2 name Living room PIR Forward Edit Send 92 92 Zone2 name Zone 2 alarm Zone1 name Zone 1 alarm Change zone name success...

Page 14: ...time to be set in seconds in all the zones for arming and disarming the alarm This enables the user to be able to enter and exit the protected rooms with enough time delay before triggering the alarm...

Page 15: ...modified as needed to disarm the alarm system from the keyboard of the control panel The password must have a minimum of 4 and a maximum of 6 digits The default password is 1234 SMS Command 13 Disarm...

Page 16: ...and sets a delay exclusively on the detectors programmed in the Delay Mode Zone However the 11 command refers to all the detectors installed The 22 command enables all the RFID devices associated with...

Page 17: ...t subsequently will follow the sequential zone numbering the first additional accessory is connected to zone 3 the second to zone 4 etc RFID TAGS the alarm system kit includes 2 RFID Tags already conn...

Page 18: ...densing Dimensions L x W x H Panel 188 x 132 x 26mm Pairing of Wireless Siren In addition to the internal siren of the control panel it is possible to add an auxiliary external wireless siren not incl...

Page 19: ...Remote Control to Disarm the System The Control Panel will beep twice and the LED light will turn off After an intrusion had been detected press the key to disarm the system and switch off the siren...

Page 20: ...rs within the rooms of the premises 2 Normal Zone Mode set on all the other sensors 3 Delay Time Zone Mode set on the door window sensor on the main entrance N B after each jumper setting modification...

Page 21: ...ys on the battery is discharged Replace the battery immediately External View Internal View Installation Remove the battery protection strip Position the transmitter on the door frame and the magnet o...

Page 22: ...ely Test Button Internal View Infrared Sensor recognises the infra red radiation emitted by the human body and activates the transmitter that will set off the alarm sound the siren send SMS and dial p...

Page 23: ...from heaters or sources of cold air air conditioners stoves fireplaces etc Do not install the sensor in rooms where there is a strong presence of steam that could cause condensation 39 40 Operative Ra...

Page 24: ...our web site http www homedefender it and read the FAQ section for further information on the return procedure DECLARATION OF COMPLIANCE HomeDefender products are built to professional standards in te...

Reviews: