2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 
2.2. General Safety Precautions 
General regulations and guidelines not mentioned in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions 
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept 
available at the operating place of the machine/unit at all 
times. Persons who are not familiar with the operating in-
structions shall not use this product. 
Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.
 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Always use personal safety equipment such as safety 

boots, rubber gloves, safety glasses and helmet. 

Make sure that the emergency exit from the work-

place is not barricaded. 

To prevent suffocation and poisoning caused by ven-

omous gases, make sure that enough oxygen exists at 
the workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third par-

ties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 
 

 
 
 
 
 
 

3. Applications and Technical Description 

3.1. Applications 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is self-assured by a 30 mA earth leakage circuit 
breaker. 
TP 50, TP 53 and TP 70 pumps are designed for pumping 
waste water, or groundwater, containing sludge or soft 
solids.  
The pumps are used for installations in public and private 
sector, trade and industry. 
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or 
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be 
checked. 
The pumps may be used for both temporary or permanent 
installation. The installation can be free-standing on a 
base-stand or by means of an auto-coupling guide rail  
system (available as accessory). 

3.2. Technical Data 

Discharge  
TP 50 

BSP 2 ½“ M 

TP 53 

BSP 3“ M 

TP 70 M...up 1,8 kW (P

2

BSP 3“ M 

TP 70 M...to 1,9 kW (P

2

) DN 

80 

TP 70 

BSP 3“ M 

Voltage  
1Ph-Motor (Model W) 

230 V 

3Ph-Motor (Model D) 

400 V 

Speed  
TP 50, TP 53 

2900 rpm 

TP 50, TP 53 M 12, M 13 V 13 

1450 rpm 

TP 70 

1450 rpm 

TP 70 V 31, V 36 

2900 rpm 

Insulation class 

Motor protection 

IP 68 

Cable 10 

Cable type 

H 07RN-F... 

Noise level during operation, 1,60 m from the 
ground 

 70d(B)A 

 
3.3. Operating Conditions 
Maximum liquid temperature:
 35°C, short term up to 
60°C. 
Density of pumped liquid: max. 1100 kg/m

3

 

Ph-value of pumped liquid: 5 up to 11. 
Level of pumped liquid: The lowest level must always 
be above the top of the pump housing (volute). 
Operation: The motors are designed for continuous op-
eration (S1) with fully submerged motor, maximum 15 
starts per hour. Our standard warranty and maintenance 
regulations refer to intermittent operation. For reduced 
warranty periods and service intervals due to continuous 
operating conditions please contact our service 
department. 

3.4. Explosive enviroments 

For operation of the pumps in explosive enviroments 

only models with explosion-proof motors (Ex model) must 
be used. 

For each individual installation the explosion classifi-

cation (Ex-class) of the pump must be approved by the 
local authorities. 
 
 
 

Summary of Contents for TP 50 Series

Page 1: ...und Bedienungsanleitung Installation and Operation Instruction Manual Montage en Bedrijfsinstrukties Manuel d instructions de montage et d exploitation 11 2004 Baureihe Series Serie S ries TP 50 TP 5...

Page 2: ...33 Pagina 34 Page 34 DEUTSCH ENGLISH NEDERLANDS FRAN AIS Elektroanschluss Electrical connection Elektrische aansluitingen Raccordement lectrique Bauma e Dimensions Afmetingen Encombrements Ersatzteil...

Page 3: ...Wir die HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid erkl ren hiermit dass die Pumpentypen TP 50 TP 53 TP 70 aufgrund Ihrer Konzipierung und Bauart sowie in der von uns in...

Page 4: ...sgesetz f r Sch den die durch unser Ger t verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleiche...

Page 5: ...e notwendigen Kondensatoren gelten folgende Daten Pumpentyp Betriebskondensator F VAC TP 50 TP 53 2polig bis 0 8 kW P2 25 450 TP 50 TP 53 2polig ber 1 0 kW P2 30 450 TP 50 TP 53 4polig bis 0 9 kW P2 4...

Page 6: ...verhindern 7 2 Na aufstellung mit autom Kupplungssystem Die nachfolgende Anleitung bezieht sich auf die Montage des Original HOMA Kupplungssystems Position von Kupplungsfu und oberer Rohrkonsole f r d...

Page 7: ...nschluss trennen um ein versehentliches Einschalten der Pumpe w hrend der Arbeit zu vermeiden Vor Beginn der Arbeit den Stillstand aller rotierenden Teile abwarten Vor Beginn der Arbeiten die Pumpe gr...

Page 8: ...Fahrtkosten des Re paraturpersonals zum und vom Einsatzort sowie Transportkosten sind nicht Bestandteil der Garantieleistung Beanstandungen deren Ursachen auf Einbau oder Bedienungsfehler unange mess...

Page 9: ...dolph Elektromotoren GmbH Ritz GmbH Pyrmonter Stra e 40 Carl Zeiss Str 33 31789 Hameln 79761 Waldshut Tiengen 0 51 51 6 10 22 0 77 41 48 80 Dietrich Wuttke GmbH Pumpen Pl tz GmbH Bahnstr 2 Sch ufelein...

Page 10: ...in line with the EC Ma chinery Directive 89 392 EEC Appendix IIA We HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and constru...

Page 11: ...by the pump due to non observance of the instructions and guidelines set forth in the operating instructions The same product liability are valid for accessories 3 Applications and Technical Descript...

Page 12: ...r than an original control unit is used make sure that the thermal relay in the motor starter is set according to the nominal current consumption of the pump motor see data on pump label Motor Start T...

Page 13: ...res and without exposing the pipe to distortion or tension Insert the guide rails in the ring of the auto coupling base and adjust the length of the rails by cutting them accurately to the guide rail...

Page 14: ...thorized service workshop Cable entry Make sure that the cable entry is watertight and that the cables are not bent sharply and or pinched Oil level and oil condition in oil chamber The oil be comes g...

Page 15: ...s defeated by a streng tech nical end control before delivery If the unit still gives an occasion for a legitimated complain you have the claim of an appropriated correction free of charge Warranty re...

Page 16: ...ijlage II A Wij HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid verklaren hiermee dat de pomp typen TP 50 TP 53 TP 70 Op grond van hun concipi ring en bouwwijze als ook in de...

Page 17: ...aakt worden wanneer de aanwijzingen en voorschriften uit deze gebruiksaanwijzing niet in acht genomen worden Voor toebehoren gelden dezelfde regels 3 Inzetbaarheid en technische 3 1 Toepassing van de...

Page 18: ...ele Homa schakelkasten zijn als toebehoor leverbaar z Schakelkastenprogramma Bij toepassing van andere schakelkasten dient men voor de keuze van de motorbeveiligingschakelaar de nennstroom van de pomp...

Page 19: ...pomp op bakstenen te plaatsen 7 2 Natte opstelling met automatisch koppelingssysteem De volgende handleiding behelst de montage van het originele HOMA koppelingsysteem Positie van de koppelingsvoet en...

Page 20: ...r inadequate reparaties welke niet door de fabrikant of een geautoriseerde vakwerplaats uitgevoerd zijn of wanneer bij onderdelenwisseling geen ORIGINELE ONDERDELEN verwerkt zijn Voor appendages gelde...

Page 21: ...voor garantie in aanmerking komende machine op de bedrijfslocatie reiskosten van het reparatiepersoneel van en naar de bedrijfslocatie als mede transportkosten zijn geen bestanddelen van onze garanti...

Page 22: ...II A Nous soussign s HOMA Pumpenfabrik GmbH Industri estrasse 1 D 53819 Neunkirchen Seelscheid certifions que les pompes sp cifi es ci dessous TP 50 TP 53 TP 70 correspondent aux exigences en mati re...

Page 23: ...3 Utilisation et caract ristiques techniques 3 1 Limites d utilisation des pompes Si les pompes sont utilis es pour le nettoyage entretien d une piscine s assurer que personne ne se trouve dans le liq...

Page 24: ...est recommand de tenir compte du courant nominal du moteur lors du choix du disjoncteur Pour les condensateurs respecter les caract ristiques suivantes Type de pompe Condensateur F VAC TP 50 TP 53 bip...

Page 25: ...d une console support fix e la cr pine d aspiration de la pompe Fixer la bride coude 90 au raccord de refoulement de la pompe Monter le tuyau de refoulement sans le tendre Respecter la r glementation...

Page 26: ...s Il est rappel que conform ment la l gislation en mati re de responsabilit du fait du produit nous ne ga rantissons pas les dommages subis par notre mat riel apr s une r paration effectu e par toutes...

Page 27: ...e accom pagn de la preuve d achat La garantie comprend la r paration des pi ces reconnues d fec tueuses Les frais de d montage et de montage du mat riel d fectueux sur le lieu d utilisation les frais...

Page 28: ...h ma de cablage pour d marrage direct stator DOL coupl en toile Normalausf hrung Standard model Normale uitvoering Version standard T1 T3 Temperaturf hler ca 130 C Nicht serienm ig auf Wunsch lieferba...

Page 29: ...H I M12 2W M17 M11 M14 450 160 231 110 R 3 AG BSP 3 M 50 271 25 111 V17 2W 465 160 231 124 R 3 AG BSP 3 M 65 271 25 111 M12 4W M13 M23 M26 V26 V13 518 177 212 101 R 3 AG BSP 3 M R 50 287 25 110 M37 V...

Page 30: ...65 305 5051 1 ISO 60 412 625 625 1000 1200 1 232 612 1 380 1 85 140 140 140 170 240 232 1 TP 53 M12 2W M17 M11 M14 450 131 81 629 335 170 DN 80 1 1 2 ISO 87 446 625 800 1 625 800 1 1000 1500 1 231 68...

Page 31: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 15 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Y...

Page 32: ...Afleveringsadres Handtekening Firmastempel 15 formulaire de commande de pi ces de rechange A HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid Fax 49 2247 70244 Type de pompe v...

Page 33: ...g 999 xx Ersatzteile f r Schaltge r t 722 Anschlu stutzen 16 Spare part list and drawings 16 1 Spare part list ATTENTION The following list contains parts that do not correspond to every pump type For...

Page 34: ...idering 719 Krimpslang 970 Typeplaat 720 Aansluitknie 990xx Motorolie 721 STA 3 delige slangkopp 999xx Onderdelen voor schakel kast 722 Aansluitring 16 Liste de pi ces d tach es et plans 16 1 Liste de...

Page 35: ...35 16 2 Ersatzteilzeichnung Spare part drawings Onderdeeltekening Plans des pi ces d tch es TP 50 M TP 53 M TP 50 M Ex TP 50 V TP 53 V TP 50 V Ex...

Page 36: ...36 TP 53 M Ex TP 53 V Ex...

Page 37: ...37 TP 70 M13 TP 70 M16 TP 70 M13 Ex TP 70 M16 Ex TP 70 V TP 70 V Ex...

Page 38: ...38 TP 70 M26 TP 70 M31 TP 70 M26 Ex TP 70 M31 Ex...

Page 39: ...39 Notes...

Page 40: ...40...

Reviews: